首页> 外文期刊>Orthopedics >Biomechanical study of 4-hole pubic symphyseal plating: Locked versus unlocked constructs
【24h】

Biomechanical study of 4-hole pubic symphyseal plating: Locked versus unlocked constructs

机译:四孔耻骨联合种植的生物力学研究:锁定与解锁结构

获取原文
获取原文并翻译 | 示例
           

摘要

To the authors' knowledge, no published studies have examined the use of locking plates on injuries of the anterior pelvic ring. The purpose of this study was to determine whether locked plates provide enhanced stability in the treatment of pubic symphyseal disruptions. Completely unstable pelvic injuries were simulated in pelvic Sawbones (model 1301; Pacific Research Laboratories, Vashon, Washington) and 2 different fixation constructs used for anterior fixation (4-hole, 3.5-mm pubic symphysis plate with all locked or all unlocked screws). Adjunctive sacroiliac screw fixation with a single 7.3-mm screw placed into S1 was used in all specimens. Specimens were analyzed for motion at the pubic symphysis and sacroiliac joints using a Material Testing System (MTS Systems Corporation, Eden Prairie, Minnesota). Each specimen was subjected to compressive loading in a single-limb stance. Side loading was also examined. The main outcome measurement was motion at the pubic symphysis and sacroiliac joints and overall construct stiffness. No significant difference existed in overall construct stiffness between the 2 methods of pubic symphysis fixation. The motions at the pubic symphysis or injured sacroiliac joints were not significantly different. In addition, motion at the pubic symphysis joint with lateral load was not improved with a locking construct. No significant difference existed between 4-hole locked or unlocked constructs used for fixation of the pubic symphysis. No apparent advantage of locking screws exists for disruptions of the pubic symphysis, and recent reports have questioned the possibility of catastrophic failure.
机译:据作者所知,尚无已发表的研究检查锁定板在骨盆前环损伤中的使用。这项研究的目的是确定锁定板是否在耻骨联合破裂的治疗中提供增强的稳定性。在骨盆Sawbones(型号1301; Pacific Research Laboratories,华盛顿州华盛顿州)和用于前路固定的2种不同固定结构(4孔,3.5毫米耻骨联合全螺钉钢板,全部锁定或未锁定)中,模拟了完全不稳定的骨盆损伤。在所有标本中均使用with骨辅助螺钉固定,单个7.3毫米螺钉插入S1中。使用材料测试系统(MTS Systems Corporation,Eden Prairie,明尼苏达州)对标本在耻骨联合和sa关节的运动进行了分析。每个标本都以单肢姿势承受压缩载荷。还检查了侧面载荷。主要结局指标是耻骨联合和sa关节运动以及整体结构刚度。两种耻骨联合固定方法在整体结构刚度上没有显着差异。耻骨联合处或sa关节受伤处的动作没有显着差异。此外,采用锁定结构不能改善耻骨联合关节的侧向负荷运动。用于固定耻骨联合的4孔锁定或未锁定结构之间没有显着差异。锁骨螺钉没有明显的优势可用于耻骨联合的破坏,并且最近的报道对灾难性故障的可能性提出了质疑。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号