首页> 外文期刊>Orthopedics >Ceramic-on-ceramic Total Hip Arthroplasty: Incidence and Risk Factors of Bearing Surface-related Noises in 125 Patients
【24h】

Ceramic-on-ceramic Total Hip Arthroplasty: Incidence and Risk Factors of Bearing Surface-related Noises in 125 Patients

机译:陶瓷-陶瓷全髋关节置换术:125例患者与轴承表面有关的噪音的发生率和危险因素

获取原文
获取原文并翻译 | 示例

摘要

The ceramic-on-ceramic bearing surface has high wear resistance and good biocom-patibility in total hip arthroplasty (THA). However, the postoperative noise problem has been an important issue. The purpose of this retrospective study was to determine the incidence and risk factors of bearing surface-related noises in patients with third-generation ceramic-on-ceramic THAs. One hundred twenty-five patients (143 hips) with ceramic-on-ceramic THAs were included in the study and followed to obtain noise and functional results. Patient factors, including sex, age, height, weight, body mass index, diagnosis, and postoperative range of motion, and surgical factors, including cup inclination, ceramic head size and length, and size of cup related to noises, were recorded. Mean follow-up was 4.2 years (range, 2-10 years). Mean Harris Hip Score was 94 points (range, 68-100 points) at latest follow-up. One (0.8%) patient had radiological evidence of osteolysis, and 4 (3.2%) patients had hip dislocation. No hip sustained a fracture of the ceramic component. Eight (6.4%) patients developed noise at their hips, including clicking in 4, grinding in 2, and snapping in 2. No patient developed squeaking hips or underwent revision surgery because of noisy hips. Younger patients (P=.O1), a diagnosis of osteonecrosis (P=.O14), a 28-mm ceramic head (P=.O42), and a higher hip range of motion postoperatively (P=.001) were related to noise in ceramic-on-ceramic THAs. The study showed third-generation ceramic-on-ceramic THAs had a low incidence of noise problems. However, long-term follow-up is necessary to determine the clinical relevance.
机译:陶瓷陶瓷支承表面在全髋关节置换术(THA)中具有很高的耐磨性和良好的生物相容性。但是,术后噪声问题一直是重要的问题。这项回顾性研究的目的是确定第三代陶瓷-陶瓷THA患者轴承表面相关噪声的发生率和危险因素。这项研究包括了125名陶瓷对陶瓷THA的患者(143髋),并对其进行了随访,以获取噪音和功能结果。记录患者因素,包括性别,年龄,身高,体重,体重指数,诊断和术后运动范围,以及手术因素,包括杯倾斜度,陶瓷头大小和长度以及与噪音相关的杯大小。平均随访时间为4.2年(范围2-10年)。在最近的随访中,平均Harris髋关节得分为94分(范围68-100分)。 1名(0.8%)患者有放射学证据表明存在骨溶解,而4名(3.2%)患者患有髋关节脱位。没有髋部承受陶瓷部件的断裂。八(6.4%)位患者的髋部产生了噪音,包括咔嗒声4次,磨削2次,咬合2次。没有患者因髋部嘈杂而出现髋部吱吱声或接受翻修手术。较年轻的患者(P = .O1),诊断为骨坏死(P = .O14),28毫米陶瓷头(P = .O42)和术后髋关节活动度更高(P = .001)与陶瓷THA中产生噪音。研究表明,第三代陶瓷对陶瓷THA的噪音问题发生率较低。但是,需要长期随访以确定临床相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号