首页> 外文期刊>Osteoarthritis and cartilage >Relationships between tibial rim alignment and joint space width measurement reproducibility in non-fluoroscopic radiographs of osteoarthritic knees.
【24h】

Relationships between tibial rim alignment and joint space width measurement reproducibility in non-fluoroscopic radiographs of osteoarthritic knees.

机译:骨关节炎膝关节的非透视射线照相中,胫骨边缘对准与关节间隙宽度测量结果可重复性之间的关系。

获取原文
获取原文并翻译 | 示例
           

摘要

RATIONALE: Superimposition of the rims of the medial tibial plateau to within 1mm is an aim of fluoroscopic knee positioning protocols for osteoarthritic (OA) knee radiography and has also been proposed as a measure of quality for non-fluoroscopic methods. OBJECTIVE: To evaluate the effect of tibial rim alignment (TRA) on reproducibility of joint space width (JSW) measurement, both were measured from radiographs taken with each tibial plateau at a range of angles determined by different non-fluoroscopic views. METHODS: TRA and JSW measurements were taken from both knees of 100 OA patients each radiographed in fully extended, schuss/tunnel, and MTP views. Degree of TRA was compared with JSW reproducibility using correlation, and between groups defined both by the 1mm threshold and by TRA-defined quartiles. RESULTS: JSW reproducibility was dependent on the degree of TRA in the fully extended and schuss/tunnel flexed knee views, although the use of the specific TRA threshold of 1mm was not supported. In the MTP view, JSW measurement was found to be highly reproducible across the full range of TRA values. CONCLUSION: These results contradict claims that TRA to within 1mm is essential for useful measurement of JSW. It is an arbitrary threshold, of use in quality control (QC) for protocols which explicitly require such alignment, and the choice of QC criteria for other protocols should be evaluated on a view-by-view basis. The results confirm previous studies showing the MTP view to afford highly reproducible JSW measurement.
机译:理由:胫骨平台内侧边缘的重叠至1mm以内是用于骨关节炎(OA)膝部射线照相的荧光镜膝关节定位协议的目标,并且还被提议作为非荧光镜方法的质量度量。目的:为了评估胫骨边缘对准(TRA)对关节间隙宽度(JSW)测量结果的可重复性的影响,这两项测量均来自于各胫骨平台所拍摄的射线照片,这些射线照片由不同的非荧光透视图确定的角度范围内。方法:TRA和JSW测量是从100例OA患者的双膝进行的,每个患者均在完全伸展的,舒张/隧道和MTP视图中进行了X线摄影。使用相关性以及在1mm阈值和TRA定义的四分位数定义的组之间,将TRA的程度与JSW的可重复性进行了比较。结果:尽管不支持使用1mm的特定TRA阈值,但JSW的可重复性取决于完全伸展和舒张/隧道屈曲的膝盖视图中TRA的程度。在MTP视图中,发现JSW测量在整个TRA值范围内都具有高度可重复性。结论:这些结果与TRA误差在1mm以内对JSW的有效测量至关重要。这是明确要求进行一致性控制的协议在质量控制(QC)中使用的任意阈值,并且应在逐个视图的基础上评估其他协议的质量控制标准的选择。结果证实了先前的研究,表明MTP观点可提供高度可重复的JSW测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号