首页> 美国卫生研究院文献>Annals of the Rheumatic Diseases >Accuracy and precision of joint space width measurements in standard and macroradiographs of osteoarthritic knees.
【2h】

Accuracy and precision of joint space width measurements in standard and macroradiographs of osteoarthritic knees.

机译:骨关节炎膝盖的标准和宏观放射线照相中关节间隙宽度测量的精度和精确度。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

OBJECTIVES--To improve the reproducibility and accuracy of joint space width (JSW) measurement as an assessment of cartilage loss in patients with osteoarthritis (OA) of the knee by determining how precision and accuracy of JSW measurement were altered by a computerised method of measurement, correction for radiographic magnification, radiography of the knee in the standing semiflexed view, and high definition macroradiography of the knee in the semiflexed view--taking JSW measurements from standard radiographs of OA knees in the extended view as the standard for comparison. METHODS--Twenty five OA and 10 nonarthritic knees were radiographed in the extended view and minimum JSW was measured manually. Conventional and x5 macroradiographs were taken in the semiflexed view. All radiographs were taken twice on the same day and repeated two weeks later. Automated computerised measurement of minimum JSW was obtained from digitally stored images of all radiographs. RESULTS--For medial compartment JSW measurements, computerised was more accurate than manual, correction for radiographic magnification improved precision and accuracy, measurements in the semiflexed view were more precise and accurate, and macroradiography increased measurement precision. For the lateral compartment JSW measurements, correction for radiographic magnification improved precision and accuracy, and the semiflexed view improved precision only. CONCLUSIONS--Protocols defining radiographic and mensural procedures are essential for quality control of knee radiography in the semiflexed view to permit accurate and reproducible measurement of JSW. Macroradiography provides greater precision of JSW measurement.
机译:目的-通过确定计算机测量方法如何改变关节间隙宽度(JSW)测量的准确性和准确性,从而提高关节间隙宽度(JSW)测量的准确性和准确性,以评估膝关节骨关节炎(OA)患者的软骨损失,放射线放大倍率的校正,站立半屈曲视图中的膝部射线照相以及半屈曲视图中的膝部高清晰度宏观射线照相-以来自扩展视野中OA膝部标准X射线照片的JSW测量作为比较标准。方法-在扩展视图中对25个OA和10个非关节炎性膝关节进行了X光照相,并手动测量了最小JSW。在半屈曲状态下拍摄了常规X射线摄片和X5射线摄片。所有射线照片在同一天拍摄两次,并在两周后重复。最小JSW的自动计算机化测量是从所有X射线照片的数字存储图像中获得的。结果-对于内侧隔室JSW测量,计算机化比手动更准确,对放射线放大倍率的校正提高了精度和准确度,在半屈曲视野中的测量更加精确和准确,而宏观射线照相术提高了测量精度。对于侧面舱室JSW测量,X射线放大倍率的校正提高了精度和准确性,而半屈曲视图仅提高了精度。结论-定义射线照相和月经程序的协议对于半屈曲视野的膝部X线照相质量控制至关重要,以便能够准确,可重复地测量JSW。宏观射线照相术可以提供更高的JSW测量精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号