...
首页> 外文期刊>Ophthalmology >Central surface curvatures of postmortem- extracted intact human crystalline lenses: implications for understanding the mechanism of accommodation.
【24h】

Central surface curvatures of postmortem- extracted intact human crystalline lenses: implications for understanding the mechanism of accommodation.

机译:尸体提取的完整人类晶状体的中心表面曲率:对于理解调节机制的意义。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To measure the radii of curvature of postmortem, whole, encapsulated human crystalline lenses, free of all zonular attachments, and to calculate their corresponding optical powers. DESIGN: Experimental study. PARTICIPANTS: Thirty human crystalline lenses from donors with a mean age of 33.6+/-14.4 years. METHODS: Intact clear human crystalline lenses were obtained within an average of 21 hours of death. The lenses were removed from the eye by the contributing eye bank and shipped in Optisol-GS, a physiologic preservative storage medium. These lenses, with intact capsules, were freed of all zonular attachments. The lenses were stored at 7 degrees C and were maintained in the same storage medium during the period that they were held for evaluation. Using a portable Keratron Scout corneal topographer (Eyequip, Ponte Vedra Beach, FL) fixed to an optical bench, the radii of curvatures of the anterior and posterior surfaces of the crystalline lens were measured daily for 10 days after receipt of the tissue. The capsules of the crystalline lenses remained intact, and the lenses were clear throughout the study. Measurements were made at room temperature after removing the lens from storage. Eight repetitions of the topography were made from each surface on each day to determine the accuracy and stability of the measurement. Profile photographs were taken daily to establish the central crystalline lens thickness. The corresponding optical power of each physiologically maintained crystalline lens was calculated. MAIN OUTCOME MEASURES: The main outcome measures were the central anterior radius of curvature, the central posterior radius of curvature, the central thickness of each crystalline lens, and the amount of change in these parameters over 10 days. RESULTS: The means +/- standard deviations of the central anterior and posterior radii of curvatures of the 30 adult lenses were 10.5+/-0.6 mm and 7.1+/-1.0 mm, respectively. The mean +/- standard deviation of the central thickness, as measured from profile photographs, was 3.9+/-0.5 mm. These mean measurements remained stable for up to 5 days after receipt of the tissue. The mean and standard deviation of the calculated optical power of these postmortem, physiologically maintained, intact human crystalline lenses from donors with a mean age of 33.6 years was 19.8+/-1.7 diopters. CONCLUSIONS: Lenses free of zonular tension are at an optical power that would be associated with optimal distance acuity.
机译:目的:测量死后,完整的,封装的人类晶状体的曲率半径,其中不包含所有小带附件,并计算其相应的光焦度。设计:实验研究。参与者:来自捐赠者的三十个人类晶状体,平均年龄为33.6 +/- 14.4岁。方法:在平均死亡21小时内获得完整透明的人类晶状体。将镜片从参与活动的眼库中移出眼睛,并装在Optisol-GS(一种生理防腐剂存储介质)中。这些具有完整囊的晶状体脱离了所有小带附件。将镜片在7℃下保存,并在保存期间将其保存在相同的存储介质中以进行评估。使用固定在光具座上的便携式Keratron Scout角膜地形图仪(Eyequip,Ponte Vedra Beach,FL),在收到组织后的10天内每天测量晶状体的前表面和后表面的曲率半径。晶状体的囊保持完整,并且在整个研究过程中晶状体是透明的。从存储中取出镜片后,在室温下进行测量。每天在每个表面上进行八次地形重复,以确定测量的准确性和稳定性。每天拍摄轮廓照片以确定中央晶状体的厚度。计算每个生理上保持的晶状体的相应光焦度。主要观察指标:主要观察指标是中央前曲率半径,中央后曲率半径,每个晶状体的中央厚度以及这些参数在10天内的变化量。结果:30个成人晶状体的曲率中心前后半径的均值+/-标准差分别为10.5 +/- 0.6 mm和7.1 +/- 1.0 mm。由轮廓照片测量的中心厚度的平均+/-标准偏差为3.9 +/- 0.5mm。这些平均测量值在收到组织后长达5天保持稳定。这些验尸,生理上维持的,完整的人类晶状体与平均年龄为33.6岁的供体的计算屈光力的平均和标准偏差为19.8 +/- 1.7屈光度。结论:无角膜张力的镜片具有与最佳距离敏锐度相关的屈光力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号