Evaluation of Internal Fit in Custom-Made Posts and Cores Fabricated with Fully Digital Versus Conventional Techniques
Objective: This study aimed to assess and compare the internal fit of custom-made posts and cores fabricated using digital impressions (DI) and conventional vinyl polysiloxane (VPS) impressions in restorative dentistry. Materials and Methods: A typodont tooth model, simulating the anatomy of the root canal of a central incisor, was utilized for the study. Two groups were formed, Group A and Group B, and each group provided a total of 18 impressions of two types: DIs and VPS impressions. In Group A, posts and cores (PCs) were fabricated using Selective Laser Melting (SLM) from the DIs. Meanwhile, in Group B, conventionally cast (CC) PCs were created from the VPS impressions. Silicone replicas of the internal surfaces were produced, and measurements were made at seven different points for each group. A statistical analysis was performed to assess the differences in internal fit between the two impression techniques. Results: The results revealed a statistically significant difference in mean internal fit between Group A (DI and SLM) and Group B (VPS and CC), with Group A exhibiting a mean internal fit of 182.6 mu m and Group B showing a mean of 205.9 mu m. While both groups demonstrated considerable variability in internal fit measurements, the digital impression technique showed promise for achieving superior internal fit, with a significantly greater fit for measuring points on sides and the most apical part of the post for Group A. Variations were observed across different measuring points, emphasizing the impact of impression technique on specific regions within the tooth. Conclusion: This study contributes to the growing body of knowledge in digital dentistry by highlighting the potential benefits of DIs in achieving a superior internal fit for custom-made PCs. Clinicians may consider the advantages of digital techniques to enhance the precision of their restorative procedures, although further research is warranted to evaluate the clinical impact of these findings.
展开▼
机译:目的:本研究旨在评估和比较在修复牙科中使用数字印模 (DI) 和传统乙烯基聚硅氧烷 (VPS) 印模制造的定制柱和芯的内部拟合。材料和方法: 该研究使用了模拟中切牙根管解剖结构的错别牙模型。分为 A 组和 B 组两组,每组共提供两种类型的 18 次展示:DI 和 VPS 展示。在 A 组中,柱子和芯 (PC) 是使用 DI 的选择性激光熔化 (SLM) 制造的。同时,在 B 组中,传统铸造 (CC) PC 是根据 VPS 印模创建的。制作了内表面的硅胶复制品,并在每组的七个不同点进行了测量。进行统计分析以评估两种印模技术之间的内部拟合差异。结果: 结果显示 A 组 (DI 和 SLM) 和 B 组 (VPS 和 CC) 的平均内部拟合存在统计学意义差异,A 组的平均内部拟合为 182.6 μ m,B 组的平均内部拟合为 205.9 μ m。虽然两组在内部拟合测量中都表现出相当大的可变性,但数字印模技术显示出实现卓越内部拟合的前景,A 组侧面和柱子最顶端部分的拟合明显更高。在不同的测量点上观察到变化,强调了印模技术对牙齿内特定区域的影响。结论:本研究通过强调 DI 在实现定制 PC 的卓越内部拟合方面的潜在好处,为数字牙科知识体系的增长做出了贡献。临床医生可能会考虑数字技术的优势来提高其修复程序的精度,尽管需要进一步的研究来评估这些发现的临床影响。
展开▼