Purpose: To explore whether a low-cost ophthalmoscope (Arclight) can be used by naive nonophthalmic examiners to effectively screen for pediatric eye disease. Methods: Fifty-four children (108 eyes) were examined by five medical students using an Arclight. Gold standard examination was performed by an ophthalmologist using a slit lamp and indirect ophthalmoscope. Examinations performed included ophthalmoscopy of the optic disc, estimation of the cup-to-disc ratio (CDR), corneal light reflex test (CRT), Bruckner's reflex test (BRT), and evaluation of refractive error. We determined the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the nonophthalmologist's Arclight exam compared to the gold standard findings of comprehensive evaluation by pediatric ophthalmologists. Results: Using the Arclight, the optic nerve exam was successfully completed in 65 of patients. CDRs above and below 0.5 could be determined with 66.7 sensitivity and 84.4 specificity. Arclight CRT measurements were significant (P < .00001) predictors of strabismus, with 80 sensitivity, 95.1, specificity, 80 PPV, and 95.1 NPV. BRT was not a significant predictor of amblyopia, with a 34.6 sensitivity, 85.7 specificity, 69.2 PPV, and 58.5 NPV. Refractive error was estimated with a success rate of 81 for emmetropia, 38 for myopia, and 21 for hyperopia. The Arclight ease-of-use was rated on average as 4.4 (SD = 0.9) on a scale of 1 to 5, with 1 being the hardest and 5 being the easiest. Conclusions: Our study shows the Arclight as an affordable and effective alternative to the traditional ophthalmoscope for assessing eye disease in children. This device can improve eye health services in under-resourced regions.
机译:目的:探讨天真的非眼科检查员是否可以使用低成本的检眼镜 (Arclight) 来有效筛查小儿眼病。方法: 5 名医学生使用 Arclight 对 54 名儿童 (108 只眼) 进行了检查。眼科医生使用裂隙灯和间接检眼镜进行黄金标准检查。进行的检查包括视盘检眼镜检查、杯盘比 (CDR) 估计、角膜光反射试验 (CRT)、布鲁克纳反射试验 (BRT) 和屈光不正评估。我们确定了非眼科医生 Arclight 检查的敏感性、特异性、阳性预测值 (PPV) 和阴性预测值 (NPV) 与儿科眼科医生综合评估的金标准结果相比。结果:使用 Arclight,65% 的患者成功完成了视神经检查。高于和低于 0.5 的 CDR 可以以 66.7% 的敏感性和 84.4% 的特异性确定。Arclight CRT 测量是斜视的显著 (P <.00001) 预测因子,敏感性为 80%,特异性为 95.1%,PPV 为 80%,NPV 为 95.1%。BRT 不是弱视的显著预测因子,敏感性为 34.6%,特异性为 85.7%,PPV 为 69.2%,NPV 为 58.5%。据估计,屈光不正治疗成功率为正视 81%,近视成功率为 38%,远视成功率为 21%。Arclight 的易用性平均评分为 4.4 (SD = 0.9) 从 1 到 5 的等级,其中 1 是最难的,5 是最容易的。结论: 我们的研究表明,Arclight 是评估儿童眼病的传统检眼镜的一种经济实惠且有效的替代品。该设备可以改善资源贫乏地区的眼健康服务。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号