首页> 外文期刊>bmj open >Comparisons of procedural characteristics and clinical outcomes between SMARTTOUCH SURROUNDFLOW catheter and other catheters for atrial fibrillation radiofrequency catheter ablation: a systematic literature review
【24h】

Comparisons of procedural characteristics and clinical outcomes between SMARTTOUCH SURROUNDFLOW catheter and other catheters for atrial fibrillation radiofrequency catheter ablation: a systematic literature review

机译:SMARTTOUCH SURROUNDFLOW 导管与其他用于心房颤动射频导管消融的手术特征和临床结果的比较:系统文献综述

获取原文
获取原文并翻译 | 示例

摘要

Background SMARTTOUCH SURROUNDFLOW (STSF) catheter is the new generation of SMARTTOUCH (ST) catheter with an upgraded irrigation system for radiofrequency catheter ablation (RFCA) in patients with atrial fibrillation (AF).Methods This systematic literature review searched the major English and Chinese bibliographic databases from 2016 to 2022 for any original clinical studies assessing the STSF catheter for RFCA in AF patients. Meta-analysis with a random effects model was used for evidence synthesis.Results Pooled outcomes from 19 included studies indicated that STSF catheter was associated with a significantly shorter procedure time (weighted mean difference (WMD): -17.4min, p<0.001), shorter ablation time (WMD: -6.6min, p<0.001) and lower catheter irrigation fluid volume (WMD: -492.7mL, p<0.001) than ST catheter. Pooled outcomes from four included studies with paroxysmal AF patients reported that using the STSF catheter for RFCA was associated with a significantly shorter ablation time (WMD: -5.7min, p<0.001) and a lower risk of 1-year postablation arrhythmia recurrence (rate ratio: 0.504, p<0.001) than the SURROUNDFLOW (SF) catheter. Significant reductions in procedure time and ablation time associated with the STSF catheter were also reported in the other four studies using non-ST/SF catheters as the control. Overall complications of STSF catheter and control catheters were comparable.Conclusions Using the STSF catheter was superior to using the ST catheter to conduct RFCA for AF by significantly reducing procedure time, ablation time, fluoroscopy time and irrigation fluid volume. The superiority of the STSF catheter over the SF catheter and other non-ST/SF catheters for RFCA needs further confirmation.
机译:背景 SMARTTOUCH SURROUNDFLOW (STSF) 导管是新一代 SMARTTOUCH (ST) 导管,具有升级的冲洗系统,用于心房颤动 (AF) 患者的射频导管消融术 (RFCA)。方法 系统文献回顾2016—2022年检索中英文主要文献数据库,检索STSF导管治疗AF患者RFCA的原始临床研究。采用随机效应模型的Meta分析进行证据综合。结果 纳入19项研究的汇总结果表明,与ST导管相比,STSF导管的手术时间(加权均数差(WMD):-17.4min,p<0.001)、消融时间(WMD:-6.6min,p<0.001)和更低的导管冲洗液量(WMD:-492.7mL,p<0.001)显著缩短。四项纳入的阵发性心房颤动患者的研究的汇总结果报告称,与SURROUNDFLOW(SF)导管相比,使用STSF导管进行RFCA与显著缩短消融时间(WMD:-5.7min,p<0.001)和更低的1年消融后心律失常复发风险(比率比:0.504,p<0.001)相关。在其他四项使用非ST/SF导管作为对照的研究中,还报告了与STSF导管相关的手术时间和消融时间的显着减少。STSF导管和对照导管的总体并发症具有可比性。结论 使用STSF导管进行AF的RFCA优于使用ST导管进行RFCA,显著减少了手术时间、消融时间、透视时间和冲洗液量。STSF 导管优于 SF 导管和其他非 ST/SF 导管用于 RFCA 的优越性需要进一步证实。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号