The response functions to mono-energetic neutrons from thermal energy to 20 MeV of eight polyethylene moderating spheres with a cylindrical proportional counter were calculated with the MCNP-4B code for each moderator and confirmed by measurements in wide neutron fields (ISO), as Am-Be and Cf-252, and with the CANEL and SIGMA IPSN Cadarache (France) facilities, which simulate realistic field and thermal neutron response. With the described spectrometry system, we have carried out neutron measurements at different points from the annular zone inside the containment building of the Vandellos II Nuclear Power Plant (Tarragona, Spain). The aim of this work is to present the results obtained during the sphere spectrometer development, with reference to the experimental and theoretical aspects and to show that our calculated spectra correspond to points of measurement compared with those obtained using the MORELPA code. (C) 2001 Elsevier Science Ltd. All rights reserved. [References: 14]
机译:使用每个主持人的MCNP-4B代码计算了八个具有圆柱比例计数器的聚乙烯减速球对从热能到20 MeV的单能中子的响应函数,并通过在宽中子场(ISO)中的测量值确认为Am- Be和Cf-252,以及CANEL和SIGMA IPSN Cadarache(法国)设施,可模拟真实的场和热中子响应。利用所描述的光谱系统,我们在Vandellos II核电厂(西班牙塔拉戈纳)的安全壳内环形区域的不同点进行了中子测量。这项工作的目的是提供球形光谱仪开发过程中获得的结果,并参考实验和理论方面,并表明与使用MORELPA代码获得的光谱相比,我们计算出的光谱对应于测量点。 (C)2001 Elsevier ScienceLtd。保留所有权利。 [参考:14]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号