首页> 外文期刊>Radiation measurements >Dose distribution of carbon ions in air assessed using imaging plates and ionization chamber
【24h】

Dose distribution of carbon ions in air assessed using imaging plates and ionization chamber

机译:使用成像板和电离室评估空气中碳离子的剂量分布

获取原文
获取原文并翻译 | 示例

摘要

A system to expose biological specimens to medium-energy (2.6-6.0 MeV/u) irradiation has been developed at the NIRS-HIMAC. In order to determine the beam energy or LET at the irradiation position in air, the dose distribution for 6.0 MeV/u carbon beam has been obtained using a secondary electron monitor and a flat-type ionization chamber by using air as the energy absorber. Imaging plates were applied to assess the beam profile distribution. The intensity of photo-stimulated luminescence (PSL) was found to be almost proportional to the energy deposited within the sensitive layer of the imaging plate. It has been confirmed that a uniform irradiation field can be produced (about +/- 5% within 20 turn in diameter) at low-intensity exposure from 10(1) to 10(4) ions/cm(2)/s. Long-term beam stability in the low-intensity condition has also been demonstrated. As a consequence, the methodology for uniform, stable and low-intensity beam exposure has been established, and the continuously variable linear energy transfer (LET) values have also been obtained by changing the distance from the endcap of beamport, for biological studies. (c) 2005 Elsevier Ltd. All rights reserved.
机译:NIRS-HIMAC已开发出一种将生物标本暴露于中能(2.6-6.0 MeV / u)辐射的系统。为了确定在空气中的照射位置处的束能量或LET,已经使用二次电子监测器和通过使用空气作为能量吸收器的平板型电离室获得了6.0 MeV / u碳束的剂量分布。应用成像板评估光束轮廓分布。发现光刺激发光(PSL)的强度几乎与沉积在成像板感光层内的能量成正比。已经证实,在从10(1)到10(4)离子/ cm(2)/ s的低强度曝光下,可以产生均匀的照射场(直径20匝内约+/- 5%)。还证明了在低强度条件下的长期光束稳定性。结果,已经建立了用于均匀,稳定和低强度光束曝光的方法,并且还通过改变距光束端口端盖的距离而获得了连续可变的线性能量转移(LET)值,用于生物学研究。 (c)2005 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号