首页> 外文期刊>Radiation measurements >Evaluation of a radiotherapy electron contamination deflecting system
【24h】

Evaluation of a radiotherapy electron contamination deflecting system

机译:放射治疗电子污染偏转系统的评估

获取原文
获取原文并翻译 | 示例

摘要

The combination of a clinically useable neodymium iron boron rare earth magnetic deflector with a clinically viable thin walled helium bag which could be placed over a patients skin has shown that it could be very effective in reducing unwanted skin dose to radiotherapy patients by the removal of unwanted lepton contamination from the entry beam while not affecting dose at depth or beam symmetry. Results have shown that up to 70% of existing dose applied to the patients skin which causes damage could be removed by the tested devices, The magnetic deflectors characteristics for interference with linear accelerator electronic components and field strengths that a patient would be exposed to are also tested. (C) 2000 Elsevier Science Ltd. All rights reserved. [References: 7]
机译:临床上可用的钕铁硼稀土磁偏转器与临床上可行的薄壁氦气袋(可以放置在患者皮肤上)的组合显示,通过去除多余的杂质,它可以非常有效地减少放射治疗患者的有害皮肤剂量入射光束中的轻子污染,但不影响深度或光束对称性时的剂量。结果表明,被测试的设备可以去除对皮肤造成损害的现有剂量的多达70%。受电磁偏转器干扰的线性加速器电子元件的特性以及患者所承受的场强也将被去除。经过测试。 (C)2000 Elsevier ScienceLtd。保留所有权利。 [参考:7]