Influence of concentration of magnesium on the dose response and LET-dependence of TL efficiency in LiF : Mg,Cu,P (MCP-N) detectors

机译:镁浓度对LiF:Mg,Cu,P(MCP-N)检测器中剂量响应和TL效率的LET依赖性的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The highly-sensitive LiF:Mg,Cu,P phosphor, unlike the supralinear LiF:Mg,Ti, exhibits a linear-sublinear dose response after high doses of photon radiation. Also, LiF:Mg,Cu,P shows a much stronger decrease of relative efficiency with increasing ionisation density, especially for heavy charged particle irradiation. The magnesium dopant most likely governs the trap structure in both phosphors. Dose-response and LET-dependence were therefore studied in LiF:Mg,Cu,P with different concentrations of Mg. Samples of LiF:Mg,Cu,P detectors with eight different values of magnesium concentration C-Mg ranging from 0.05 to 0.8 mol%, were produced in which the Concentration of P and Cu was fixed at 1.25 and 0.05 mol%, respectively. Detectors were irradiated with 5.3 MeV alpha-particles and Cs-137 gamma-rays and relative efficiency evaluated for all groups of samples. Relative efficiency eta(alpha gamma) appears to decrease with increasing magnesium content: from eta(alpha gamma) approximate to 0.13 at C-Mg = 0.05 mol% to eta(alpha gamma) approximate to 0.06 at C-Mg = 0.20 mol%, and is less dependent on C-Mg at higher concentration of Mg. In the study of LiF:Mg,Cu,P response after Cs-137 photon doses (1-1000 Gy) in samples with C-Mg = 0.1 and 0.2 mol%, typical sublinear response was observed, the sublinearity of 0.1 mol% detectors commencing at higher doses. In contrast, in the least Mg-doped sample (0.05 mol%) strong supralinearity in the dose response was found, resulting from the growth of a new peak at about 200 degrees C which at 1000 Gy and at 500 Gy dominates the TL glow-curve over the usual main peak at 240 degrees C. (C) 1998 Elsevier Science Ltd. All rights reserved. [References: 9]
机译:与超线性LiF:Mg,Ti不同,高灵敏度LiF:Mg,Cu,P磷光体在高剂量的光子辐射后表现出线性-亚线性剂量响应。而且,LiF:Mg,Cu,P随电离密度的增加显示出相对效率的明显降低,特别是对于重电荷粒子辐照而言。镁掺杂剂最有可能控制两种磷光体中的陷阱结构。因此研究了LiF:Mg,Cu,P中不同浓度的Mg的剂量反应和LET依赖性。制备了LiF:Mg,Cu,P检测器的样品,其镁浓度C-Mg的八个不同值在0.05到0.8 mol%之间,其中P和Cu的浓度分别固定为1.25和0.05 mol%。用5.3 MeVα粒子和Cs-137γ射线照射检测器,并评估所有样品组的相对效率。相对效率eta(alpha gamma)似乎随着镁含量的增加而降低:从eta(alpha gamma)在C-Mg = 0.05 mol%时约为0.13到eta(alpha gamma)在C-Mg = 0.20 mol%时约为0.06,在较高的Mg浓度下,对C-Mg的依赖性较小。在C-Mg = 0.1和0.2 mol%的样品中Cs-137光子剂量(1-1000 Gy)后LiF:Mg,Cu,P响应的研究中,观察到典型的亚线性响应,0.1 mol%检测器的亚线性从更高剂量开始。相比之下,在掺杂最少的Mg(0.05 mol%)的样品中,发现剂量响应中存在超线性,这是由于在200 G左右出现了一个新峰,该峰在1000 Gy和500 Gy时占主导地位,曲线在240摄氏度时超过通常的主峰。(C)1998 Elsevier ScienceLtd。保留所有权利。 [参考:9]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号