Multiple scattering of gamma photons obtained from 0.215 GBq Cs-137 source in both forward and backward hemisphere for 4 elements viz., carbon, aluminium, iron and copper are detected by a 76 mm x 76 mm Nal(Tl) scintillation detector. The variation of saturation thicknesses of 4 elements are studied experimentally at 60 degrees, 80 degrees, 90 degrees, 100 degrees, 120 degrees and 135 degrees. Monte Carlo N-Particle (MCNP) simulation of multiple scattering and variation in saturation thicknesses is carried out for 40 degrees, 60 degrees, 80 degrees, 90 degrees, 100 degrees, 120 degrees, 135 degrees, 160 degrees and 180 degrees for four elements. The variation of the intensity of multiple scattered photons in different scattering angles is found to be different in forward and backward hemispheres. The intensity of multiple scattered photons is found to be minimum at around 90 degrees. Saturation thicknesses for 40 degrees and 60 degrees are found to be less than saturation thicknesses for 80 degrees, 90 degrees, 100 degrees, 120 degrees, 135 degrees, 160 degrees and 180 degrees in spite of the fact that the scattered energy is more for lower scattering angles. The behaviour of variation of saturation thicknesses as a function of scattering angles obtained from MCNP simulation agrees well with experimentally obtained values. (C) 2015 Elsevier Ltd. All rights reserved.
机译:通过76 mm x 76 mm Nal(Tl)闪烁检测器检测到从0.215 GBq Cs-137源在正向和反向半球中获得的4个元素(碳,铝,铁和铜)在前半球和后半球的伽马光子的多次散射。在60度,80度,90度,100度,120度和135度的实验条件下研究了4种元素的饱和厚度的变化。对40度,60度,80度,90度,100度,120度,135度,160度和180度的四个元素进行了饱和厚度的多重散射和变化的蒙特卡罗N粒子(MCNP)模拟。发现在前半球和后半球中,多个散射光子在不同散射角下的强度变化是不同的。发现多个散射光子的强度在90度左右最小。尽管40°和60度的饱和厚度小于80度,90度,100度,120度,135度,160度和180度的饱和厚度,但较低的散射能量更大散射角。从MCNP模拟获得的饱和厚度随散射角变化的行为与实验获得的值非常吻合。 (C)2015 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号