This paper presents results of electrical property measurements on EPR-based insulations of low-voltage power cables used in nuclear power plants. The specimens underwent accelerated aging through the simultaneous application of high temperature and gamma-radiation. Mechanical properties and the dielectric response at different frequencies were investigated. Results showed significant variation of the electrical and mechanical properties of aged cables at low frequencies, i.e. lower than 10~(-2) Hz. In particular, the real and imaginary parts of permittivity increase with aging time, accumulated dose and stress levels applied showing good correlation with elongation at break, which decreases as a function of extent of insulation aging.
机译:本文介绍了用于核电站的低压电力电缆基于EPR的绝缘体的电性能测量结果。通过同时施加高温和伽马射线,样品经历了加速老化。研究了不同频率下的机械性能和介电响应。结果表明,老化的电缆在低频(即低于10〜(-2)Hz)下的电气和机械性能有很大变化。特别地,介电常数的实部和虚部随着老化时间的增加而增加,所施加的累积剂量和应力水平显示出与断裂伸长率的良好相关性,其随着绝缘老化程度的降低而降低。