A method to improve target dose homogeneity of craniospinal irradiation using dynamic split field IMRT.

机译:一种使用动态分裂场IMRT改善颅骨照射目标剂量均匀性的方法。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: Craniospinal irradiation (CSI) is technically very challenging and field edge matching is needed because of the mechanical limitations of standard linear accelerators. We assessed the feasibility of intensity-modulated radiotherapy (IMRT) in CSI to overcome the standard feathering and dose inhomogeneities associated with the standard feathering technique in the junction areas. MATERIALS AND METHODS: The use of IMRT in CSI was studied with five patients CT scanned in the supine position. Isocentric treatment plans of three dimensional conventional radiotherapy (3D-CRT) and split field IMRT (sfIMRT) with dynamic intrafractional feathering were created with the same field setup and the resulted dose distributions were compared. The effect of treatment inaccuracy was simulated with an intentional shift of +/-3mm with both treatment plans. Dosimetric verification of the sfIMRT treatment plan was performed with radiographic films placed in a phantom. RESULTS: The sfIMRT treatment plans resulted in a better dose coverage and uniformity in the target volume. The +/-3mm shift had only a minor effect on the dose distribution of the sfIMRT treatment plan whereas with the 3D-CRT the shift resulted in an error of +/-38% of the calculated dose in the spinal cord. The measured dose distribution of the sfIMRT treatment plan correlated well with the calculations. CONCLUSIONS: Improved dose homogeneity in the target volume was achieved with the sfIMRT compared to the conventional 3D-CRT treatment plan. With the sfIMRT technique only a single treatment plan is required to deliver the total treatment dose and the resulting dose distribution is also less volatile for technical uncertainties of the treatment.
机译:目的:颅脊髓照射(CSI)在技术上非常具有挑战性,并且由于标准线性加速器的机械限制,需要进行场边缘匹配。我们评估了CSI中强度调制放射疗法(IMRT)克服在交界处的标准羽化和与标准羽化技术相关的剂量不均匀性的可行性。材料和方法:研究了5名患者仰卧位CT扫描中IMRT在CSI中的应用。在相同的场设置下创建了三维常规放射疗法(3D-CRT)和具有动态分数内羽化的裂区IMRT(sfIMRT)的等中心治疗计划,并比较了剂量分布。在两个治疗计划中,有意移动+/- 3mm来模拟治疗不准确的影响。 sfIMRT治疗计划的剂量学验证是通过将幻影胶片放置在体模中进行的。结果:sfIMRT治疗计划导致更好的剂量覆盖范围和目标体积的均一性。 +/- 3mm偏移对sfIMRT治疗计划的剂量分布影响很小,而3D-CRT偏移则导致脊髓计算剂量的误差+/- 38%。 sfIMRT治疗计划的测量剂量分布与计算结果非常相关。结论:与传统的3D-CRT治疗计划相比,sfIMRT可提高目标体积的剂量均一性。使用sfIMRT技术,只需一个单一的治疗计划即可提供总治疗剂量,并且由于治疗的技术不确定性,最终的剂量分布波动性也较小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号