PURPOSE: To investigate setup discrepancies measured with ExacTrac X-ray 6 degree-of-freedom (6D) and cone-beam computed tomography (CBCT) for patients under treatments of stereotactic body radiation therapy (SBRT). MATERIALS AND METHODS: In this work, phantom and patient studies were performed. In the phantom studies, an anthropomorphic phantom was placed with pre-defined positions, and imaged with ExacTrac X-ray 6D and CBCT to test the accuracy of the imaging systems. In the patient studies, 16 spinal SBRT patient cases were retrospectively analyzed. The patients were initially positioned in customized immobilization cradles and then aligned with ExacTrac X-ray 6D and CBCT. The setup discrepancies were computed and quantitatively analyzed. RESULTS: This study indicates modest discrepancies between ExacTrac X-ray 6D and CBCT with spinal SBRT. The phantom experiments showed that translational and rotational discrepancies in root-mean-square (RMS) between ExacTrac X-ray 6D and CBCT were, respectively, <1.0mm and <1 degrees . In the retrospective patient studies, translational and rotational discrepancies in RMS between ExacTrac X-ray 6D and CBCT were <2.0mm and <1.5 degrees . CONCLUSIONS: ExacTrac X-ray 6D represents a potential alternative to CBCT; however, pre-caution should be taken when only ExacTrac X-ray 6D is used to guide SBRT with small setup margins.
机译:目的:研究用ExacTrac X射线6自由度(6D)和锥束计算机断层扫描(CBCT)测量的立体定向身体放射疗法(SBRT)患者的设置差异。材料与方法:在这项工作中,进行了幻像和患者研究。在体模研究中,将拟人体模放置在预定位置,并用ExacTrac X射线6D和CBCT成像以测试成像系统的准确性。在患者研究中,回顾性分析了16例脊柱SBRT患者。患者最初被放置在定制的固定支架中,然后与ExacTrac X射线6D和CBCT对准。设置差异进行了计算和定量分析。结果:这项研究表明ExacTrac X射线6D和CBCT与脊柱SBRT之间存在适度的差异。幻像实验表明,ExacTrac X射线6D和CBCT之间的均方根(RMS)的平移和旋转差异分别小于<1.0mm和<1度。在回顾性患者研究中,ExacTrac X射线6D和CBCT之间RMS的平移和旋转差异分别为<2.0mm和<1.5度。结论:ExacTrac X射线6D可以替代CBCT。但是,当仅使用ExacTrac X射线6D引导具有较小设置余量的SBRT时,应采取预防措施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号