首页> 美国卫生研究院文献>other >Evaluations of the setup discrepancy between BrainLAB 6D ExacTrac and cone-beam computed tomography used with the imaging guidance system Novalis-Tx for intracranial stereotactic radiosurgery
【2h】

Evaluations of the setup discrepancy between BrainLAB 6D ExacTrac and cone-beam computed tomography used with the imaging guidance system Novalis-Tx for intracranial stereotactic radiosurgery

机译:评估颅内立体定向放射外科成像引导系统Novalis-Tx所使用的BrainLAB 6D ExacTrac与锥束计算机断层扫描之间的设置差异

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The objective of this study was to evaluate the setup discrepancy between BrainLAB 6 degree-of-freedom (6D) ExacTrac and cone-beam computed tomography (CBCT) used with the imaging guidance system Novalis Tx for intracranial stereotactic radiosurgery. We included 107 consecutive patients for whom white stereotactic head frame masks (R408; Clarity Medical Products, Newark, OH) were used to fix the head during intracranial stereotactic radiosurgery, between August 2012 and July 2016. The patients were immobilized in the same state for both the verification image using 6D ExacTrac and online 3D CBCT. In addition, after radiation treatment, registration between the computed tomography simulation images and the CBCT images was performed with offline 6D fusion in an offline review. The root-mean-square of the difference in the translational dimensions between the ExacTrac system and CBCT was <1.01 mm for online matching and <1.10 mm for offline matching. Furthermore, the root-mean-square of the difference in the rotational dimensions between the ExacTrac system and the CBCT were <0.82° for online matching and <0.95° for offline matching. It was concluded that while the discrepancies in residual setup errors between the ExacTrac 6D X-ray and the CBCT were minor, they should not be ignored.
机译:这项研究的目的是评估BrainLAB 6自由度(6D)ExacTrac和与影像引导系统Novalis Tx一起用于颅内立体定向放射外科手术的锥束计算机断层扫描(CBCT)之间的设置差异。我们纳入了2012年8月至2016年7月期间在颅内立体定向放射外科手术中使用白色立体定向头罩(R408; Clarity Medical Products,Newark,OH)固定头部的107例患者。使用6D ExacTrac和在线3D CBCT的验证图像。另外,在放射线治疗之后,在离线审查中使用离线6D融合在计算机断层扫描模拟图像和CBCT图像之间进行配准。 ExacTrac系统与CBCT之间的平移尺寸差异的均方根值对于在线匹配为<1.01 mm,对于离线匹配为<1.10 mm。此外,ExacTrac系统与CBCT之间的旋转尺寸之差的均方根对于在线匹配为<0.82°,对于离线匹配为<0.95°。结论是,尽管ExacTrac 6D X射线和CBCT之间的残留设置误差不大,但不应忽略它们。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号