首页> 外文期刊>Research report NIFS-PROC series >Progress of Positive-Ion-Based NBI for LHD
【24h】

Progress of Positive-Ion-Based NBI for LHD

机译:LHD正离子基NBI研究进展

获取原文
获取原文并翻译 | 示例

摘要

Two positive-ion-based neutral injectors for Large Helical Device (LHD), which are LHD-NBI #4 and #5, are overviewed. Those injectors are installed to enhance the ion temperature of LHD plasmas by producing low-temperature ions. Each beamline has four ion sources, and the injection power of NBI #4 is 6 MW at the energy of 40 keV.The NBI #5 is designed to provide the beam power of 6 MW at 45 keV for hydrogen beam and 9 MW at 80 keV for deuterium beam. Beam injection with NBI #4 has started with two ion sources in 2004 and with full of four sources in 2005. The maximum power of NBI #4 has reached 7 MW. The injector contributes to increase ion temperature, and is also applied to a diagnostic beam using charge exchange recombination spectroscopy (CXRS). The NBI #5 has been operational in 2010. After tuning a ratio of acceleration and deceleration voltages, the injection power reaches 5.8 MW at 40 keV so far.
机译:概述了两种用于大型螺旋装置(LHD)的基于阳离子的中性喷油器,分别是LHD-NBI#4和#5。安装这些注射器是通过产生低温离子来提高LHD等离子体的离子温度。每条束线有四个离子源,NBI#4的注入功率在40 keV时为6 MW.NBI#5旨在为45 keV的氢束提供6 MW的束功率,在80 keV的情况下提供9 MW的束功率氘束的keV。 NBI#4的束流注入从2004年的两个离子源开始,到2005年已经有四个离子源。NBI#4的最大功率已达到7 MW。注入器有助于提高离子温度,并使用电荷交换复合光谱(CXRS)应用于诊断束。 NBI#5已于2010年投入使用。调整加速和减速电压的比例后,到目前为止,在40 keV时,注入功率达到5.8 MW。