...
首页> 外文期刊>Reproduction in Domestic Animals >Evaluation of methods to determine sperm density for the European eel, Anguilla anguilla.
【24h】

Evaluation of methods to determine sperm density for the European eel, Anguilla anguilla.

机译:评价确定欧洲鳗,(Anguilla anguilla)精子密度的方法。

获取原文
获取原文并翻译 | 示例
           

摘要

European eel, Anguilla anguilla, is a target species for future captive breeding, yet best methodology to estimate sperm density for application in in vitro fertilization is not established. Thus, our objectives were to evaluate methods to estimate European eel sperm density including spermatocrit, computer-assisted sperm analysis (CASA) and flow cytometry (FCM), using Neubauer Improved haemocytometer as benchmark. Initially, relationships between spermatocrit, haemocytometer counts and sperm motility were analysed, as well as the effect of sperm dilution on haemocytometer counts. Furthermore, accuracy and precision of spermatocrit, applying a range of G-forces, were tested and the best G-force used in method comparisons. We found no effect of dilution on haemocytometer sperm density estimates, whereas motility associated positively with haemocytometer counts, but not with spermatocrit. Results from all techniques, spermatocrit, CASA and FCM, showed significant positive correlations with haemocytometer counts. The best correlation between spermatocrit and haemocytometer counts was obtained at 6000 x g (r=0.68). Of two CASA variants, one or three photographic fields (CASA-1 and CASA-2), CASA-2 showed a very high accuracy to haemocytometer counts (r=0.93), but low precision (CV: CASA-2=28.4%). FCM was tested with and without microfluorospheres (FCM-1 and FCM-2), and relationships to haemocytometer counts were highly accurate (FCM-1: r=0.94; FCM-2: r=0.88) and precise (CV: FCM-1=2.5; FCM-2=2.7%). Overall, CASA-2 and FCM-1 feature reliable methods for quantification of European eel sperm, but FCM-1 has a clear advantage featuring highest precision and accuracy. Together, these results provide a useful basis for gamete management in fertilization protocols.
机译:欧洲鳗鳗(Anguilla anguilla)是未来圈养繁殖的目标物种,但尚未建立评估用于体外受精的精子密度的最佳方法。因此,我们的目标是使用Neubauer改进型血细胞计数器作为基准,评估评估欧洲鳗精子密度的方法,包括精细胞比容,计算机辅助精子分析(CASA)和流式细胞仪(FCM)。最初,分析了精细胞压积,血细胞计数和精子活力之间的关系,以及精子稀释对血细胞计数的影响。此外,还测试了施加一定范围的G力的精细胞压积的准确性和精确度,并在方法比较中使用了最佳的G力。我们发现稀释对血细胞计数器的精子密度估计没有影响,而运动性与血细胞计数器的数量呈正相关,但与精细胞比容没有正相关。精细胞比容,CASA和FCM等所有技术的结果均与血细胞计数器计数呈显着正相关。在6000 x g(r = 0.68)处获得了精细胞比容和血细胞计数器之间的最佳相关性。在两个CASA变体中,一个或三个摄影场(CASA-1和CASA-2)中,CASA-2相对于血细胞计数器计数显示出非常高的准确度(r = 0.93),但准确性却很低(CV:CASA-2 = 28.4%) 。在有或没有微荧光球(FCM-1和FCM-2)的情况下测试了FCM,并且与血细胞计数器计数的关系非常准确(FCM-1:r = 0.94; FCM-2:r = 0.88)和精确(CV:FCM-1 = 2.5; FCM-2 = 2.7%)。总体而言,CASA-2和FCM-1具有可靠的欧洲鳗精子定量方法,但FCM-1具有明显的优势,具有最高的精确度和准确性。总之,这些结果为受精方案中的配子管理提供了有用的基础。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号