We introduce a two-component matrix for ultraviolet matrix-assisted laser desorption/ionization mass spectrometry (UV-MALDI-MS) that consists of 2,5-dihydroxybenzoic acid (DHB) and glycerol. Upon slow evaporation of residual water/methanol solvents in a pre-vacuum chamber sample preparations are obtained that exhibit a homogeneous morphology with analyte-matrix crystals evenly distributed over the whole sample spot. At a molar DHB/glycerol ratio of similar to 1:5, the crystals range in length from similar to 100 to 300 mu m and are about 15-30 mu m wide. Mass spectra of peptides, proteins, and an oligosaccharide are presented and compared with those recorded from standard dried-droplet DHB matrix. The ion signals show a reproducibility of the order of 10-15% when scanning the surface of an individual sample or even different samples that contain the same amount of peptide, A close to linear relationship between peptide concentration and the corresponding peptide ion signal is found over three orders of magnitude of sample prepared. However, when a fixed position is irradiated with a large number of laser pulses, a monotonous decay of peptide ion signal with time is observed. Potentially, the binary matrix will be especially useful for the analysis of samples that are stabilized in buffered aqueous glycerol solution and preliminary results addressing this aspect are shown. Copyright (C) 2007 John Wiley & Sons, Ltd.
机译:我们介绍了一种由2,5-二羟基苯甲酸(DHB)和甘油组成的用于紫外线基质辅助激光解吸/电离质谱(UV-MALDI-MS)的两组分基质。在预真空室中缓慢蒸发残留的水/甲醇溶剂后,将获得样品制剂,样品制剂表现出均一的形态,分析物-基质晶体均匀分布在整个样品点上。在DHB /甘油的摩尔比大约为1:5时,晶体的长度范围从大约100到300μm,并且宽约15-30μm。给出了肽,蛋白质和寡糖的质谱图,并将其与标准干滴DHB基质记录的质谱图进行了比较。当扫描单个样品甚至包含相同量肽的不同样品的表面时,离子信号的可再现性约为10-15%。发现肽浓度与相应肽离子信号之间的线性关系接近制备的样品数量超过三个数量级。然而,当用大量激光脉冲照射固定位置时,观察到肽离子信号随时间单调衰减。潜在地,该二元基质将特别适用于分析在甘油缓冲水溶液中稳定的样品,并显示了解决该问题的初步结果。版权所有(C)2007 John Wiley&Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号