Evidence for bias in measured δ~(15)N values of terrestrial and aquatic organic materials due to pre-analysis acid treatment methods

机译:分析前酸处理方法对陆生和水生有机物质的δ〜(15)N值的偏倚证据

获取原文
获取原文并翻译 | 示例
           

摘要

We investigate the effect of acid treatment methods on δ ~(15)N values from a range of environmental organic materials in the context of the increased application of 'dual-mode' isotope analysis (the simultaneous measurement of δ~(13)C and δ~(15)N from the same acid-treated sample). Three common methods are compared; (i) untreated samples; (ii) acidification followed by sequential water rinse (rinse method); and (iii) acidification in silver capsules (capsule method). The influence of capsule type (silver and tin) on δ~(15)N is also independently assessed (as the capsule and rinse methods combust samples in different capsules; silver and tin, respectively). We find significant differences in δ~(15)N values between methods and the precision of any one method varies significantly between sample materials and above the instrument precision (>0.3‰). The δ~(15)N values of untreated samples did not produce the most consistent data on all sample materials. In addition, the capsule type appears to influence the measured δ~(15)N value of some materials, particularly those combusted only in silver capsules. We also compare the new δ~(15)N data with previously published δ~(13)C data on the same materials. The response of δ~(13)C and δ~(15)N within and between methods and sample materials to acidification appears to be relatively disproportionate, which can influence the environmental interpretation of the measured data. In addition, statistical methods used to estimate inorganic nitrogen are shown to be seriously flawed.
机译:在“双模”同位素分析(同时测量δ〜(13)C和δ的同时测量)的背景下,我们研究了酸处理方法对一系列环境有机材料中δ〜(15)N值的影响。来自相同酸处理样品的δ〜(15)N)。比较了三种常见方法; (i)未经处理的样品; (ii)酸化,然后依次用水冲洗(冲洗法); (iii)银胶囊中的酸化(胶囊法)。还可以独立评估胶囊类型(银和锡)对δ〜(15)N的影响(因为胶囊和冲洗方法会燃烧不同胶囊中的样品;分别是银和锡)。我们发现两种方法之间的δ〜(15)N值存在显着差异,并且任何一种方法的精度在样品材料之间且显着高于仪器精度(> 0.3‰)时都存在很大差异。未经处理的样品的δ〜(15)N值并未在所有样品材料上产生最一致的数据。此外,胶囊的类型似乎会影响某些材料(尤其是仅在银质胶囊中燃烧的材料)的δ〜(15)N值。我们还将相同材料上的新δ〜(15)N数据与先前发布的δ〜(13)C数据进行比较。方法和样品材料内部和之间的δ〜(13)C和δ〜(15)N对酸化的响应似乎不成比例,这可能会影响测量数据的环境解释。此外,用于估算无机氮的统计方法也显示出严重缺陷。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号