首页> 外文期刊>Rapid Communications in Mass Spectrometry: RCM >Strontium isotope ratios (Sr-87/Sr-86) of tooth enamel: a comparison of solution and laser ablation multicollector inductively coupled plasma mass spectrometry methods
【24h】

Strontium isotope ratios (Sr-87/Sr-86) of tooth enamel: a comparison of solution and laser ablation multicollector inductively coupled plasma mass spectrometry methods

机译:牙釉质的锶同位素比(Sr-87 / Sr-86):溶液和激光烧蚀多收集器电感耦合等离子体质谱法的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Strontium isotope ratios (Sr-87/Sr-86) in tooth enamel provide a means to investigate migration and landscape use in humans and other animals. Established methods for measuring Sr-87/Sr-86 in teeth use bulk sampling (5-20 mg) and labor-intensive elemental purification procedures before analysis by either thermal ionization mass spectrometry (TIMS) or multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS). Another method for measuring Sr-87/Sr-86 is laser ablation MC-ICP-MS, but concerns have been expressed about its accuracy for measuring tooth enamel. In this study we test the precision and accuracy of the technique by analyzing 30 modem rodent teeth from the Sterkfontein Valley, South Africa by laser ablation MC-ICP-MS and solution MC-ICP-MS. The results show a mean difference in Sr-87/Sr-86 measured by laser ablation and by solution of 0.0003 +/- 0.0002. This degree of precision is well within the margin necessary for investigating the potential geographic origins of humans or animals in many areas of the world. Because laser ablation is faster, less expensive, and less destructive than bulk sampling solution methods, it opens the possibility for conducting Sr-87/Sr-86 analyses of intra-tooth samples and small and/or rare specimens such as micromammal and fossil teeth. Copyright (C) 2008 John Wiley & Sons, Ltd.
机译:牙齿珐琅质中的锶同位素比(Sr-87 / Sr-86)提供了一种手段来研究人类和其他动物的迁移和景观用途。建立的测量牙齿中Sr-87 / Sr-86的方法使用大量采样(5-20​​ mg)和劳动密集型元素纯化程序,然后通过热电离质谱(TIMS)或多收集器电感耦合等离子体质谱(MC- ICP-MS)。测量Sr-87 / Sr-86的另一种方法是激光烧蚀MC-ICP-MS,但人们对其测量牙釉质的准确性表示担忧。在这项研究中,我们通过激光剥蚀MC-ICP-MS和溶液MC-ICP-MS分析了南非Sterkfontein谷地的30个现代啮齿动物牙齿,测试了该技术的精度和准确性。结果显示通过激光烧蚀和溶液测量的Sr-87 / Sr-86的平均差异为0.0003 +/- 0.0002。这种精确度完全在调查世界许多地区人类或动物潜在地理起源所必需的范围之内。由于激光烧蚀比批量采样解决方案方法更快,更便宜且破坏性更小,因此它为进行牙齿内样本以及小型和/或稀有样本(如微型哺乳动物和化石牙齿)的Sr-87 / Sr-86分析提供了可能性。版权所有(C)2008 John Wiley&Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号