首页> 外文期刊>Rapid Communications in Mass Spectrometry: RCM >A method for routine quantitation of urinary 8-hydroxy-2 '-deoxyguanosine based on solid-phase extraction and micro-high-performance liquid chromatography electrospray ionization tandem mass spectrometry
【24h】

A method for routine quantitation of urinary 8-hydroxy-2 '-deoxyguanosine based on solid-phase extraction and micro-high-performance liquid chromatography electrospray ionization tandem mass spectrometry

机译:基于固相萃取和微高效液相色谱电喷雾电离串联质谱的尿中8-羟基-2'-脱氧鸟苷的常规定量方法

获取原文
获取原文并翻译 | 示例

摘要

8-Hydroxy-2'-deoxyguanosine (8OHdG), one of the major oxidative DNA lesions induced by radical agents, is commonly used as a biomarker for oxidative stress, nowadays preferably in urine. In the absence of a commercially available internal standard a micro-high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (micro-HPLC/ESI-MS/MS) method, suitable for routine analysis of 8OHdG in human urine using external calibration, was developed. Evaluation of the matrix effect showed that the method allows highly sensitive and accurate quantitation despite the absence of an internal standard. HPLC analysis was performed using gradient elution at a flow rate of 10 muL min(-1) using a capillary reversed-phase column and an injection volume of 0.5 muL, with detection of 8OHdG in positive multiple reaction monitoring (MRM) mode. The absolute limit of detection was 0.35 fmol using m/z 168 as a quantifier (fragment) ion. A linear (R-2 > 0.999) calibration curve in urine was obtained over a range 0.2-10 ng mL(-1). This method is about 20 times more sensitive than previously described procedures, and is characterized by high accuracy (mean 90%) and good reproducibility (RSD < 10%). The optimized method was applied to determination of 8OHdG in 18 urinary samples derived from three healthy volunteers. 8OHdG urinary excretion ranged from 3.0-7.9 mug/day, and a large intra-individual variation was found. This method, which effectively circumvents the need for isotopically labeled 8OHdG (internal standard), is suitable for routine monitoring of exposure to DNA-damaging factors in a large number of subjects. Copyright (C) 2004 John Wiley Sons, Ltd.
机译:8-羟基-2'-脱氧鸟苷(8OHdG)是自由基试剂诱导的主要氧化性DNA损伤之一,通常被用作氧化应激的生物标记物,如今在尿液中尤为理想。在没有市售内标的情况下,适用于使用外部校准对人尿中的8OHdG进行常规分析的微高效液相色谱/电喷雾串联质谱法(micro-HPLC / ESI-MS / MS)发达。对基质效应的评估表明,尽管没有内标,该方法仍可实现高度灵敏和准确的定量。 HPLC分析是使用毛细管反相色谱柱,流速为10μLmin(-1),使用毛细管反相色谱柱,进样体积为0.5μL的梯度洗脱进行的,并在正多反应监测(MRM)模式下检测8OHdG。使用m / z 168作为定量离子(片段),检测的绝对极限为0.35 fmol。在0.2-10 ng mL(-1)范围内获得尿液的线性(R-2> 0.999)校准曲线。该方法的灵敏度比先前描述的方法高20倍左右,并且具有较高的准确性(平均90%)和良好的可重复性(RSD <10%)。该优化方法用于测定来自三名健康志愿者的18份尿样中的8OHdG。 8OHdG的尿排泄量为3.0-7.9杯/天,并且发现个体内差异很大。该方法有效地避免了对同位素标记的8OHdG(内标)的需要,适用于常规监测大量受试者中DNA破坏因子的暴露情况。版权所有(C)2004 John Wiley Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号