首页> 外文期刊>Radiology >MR flow mapping in coronary artery bypass grafts: a validation study with Doppler flow measurements.
【24h】

MR flow mapping in coronary artery bypass grafts: a validation study with Doppler flow measurements.

机译:冠状动脉旁路移植术中的MR流图:多普勒血流测量的验证研究。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To validate fast magnetic resonance (MR) flow mapping with intravascular Doppler flow measurements in vitro and in patients with nonstenotic and stenotic coronary artery bypass grafts. MATERIALS AND METHODS: MR and Doppler flow measurements were performed in a small-diameter flow phantom with physiologic flow conditions and at baseline and during adenosine stress in 27 grafts in 23 patients, who were scheduled for cardiac catheterization. At invasive analysis, the grafts were divided into those with stenosis of less than 50% (nonstenotic) and those with stenosis greater than or equal to 50% (stenotic). In vitro velocity values and velocity values in nonstenotic and stenotic grafts were compared with linear regression analysis, and the in vitro interstudy variability was determined. RESULTS: Excellent correlations in average peak velocity (r = 0.99, P <.001) and diastolic peak velocity (r = 0.99, P <.001) were demonstrated in vitro between MR and Doppler flow measurements, with less than 5% interstudy variability. MR and Doppler flow measurements revealed good correlations in peak velocity and velocity reserve both in nonstenotic (n = 20) (average peak velocity: r = 0.81, P <.001; diastolic peak velocity: r = 0.83, P <.001; velocity reserve: r = 0.56, P =.010) and stenotic (n = 7) (average peak velocity: r = 0.83, P <.001; diastolic peak velocity: r = 0.78, P =.001; velocity reserve: r = 0.70, P =.078) grafts. CONCLUSION: Fast MR flow mapping provides noninvasive measures of peak velocity and velocity reserve, which closely correlate with Doppler values both in vitro and in nonstenotic and stenotic grafts.
机译:目的:通过体外和非狭窄和狭窄冠状动脉旁路移植术患者,通过血管内多普勒血流测量来验证快速磁共振(MR)血流图。材料与方法:MR和多普勒血流测量是在具有生理血流状况的基线小直径血流模型中进行的,在基线和腺苷应激期间对23例计划进行心脏导管插入术的27例患者进行了测量。在进行侵入性分析时,将移植物分为狭窄程度小于50%的那些(非狭窄)和狭窄程度大于或等于50%的那些(狭窄)。用线性回归分析比较非狭窄和狭窄移植物中的体外速度值和速度值,并确定体外研究间的变异性。结果:MR和多普勒血流测量值之间的平均峰值速度(r = 0.99,P <.001)和舒张期峰值速度(r = 0.99,P <.001)具有良好的相关性,研究间变异小于5% 。 MR和多普勒血流测量显示在非狭窄(n = 20)中峰值速度和速度储备均具有良好的相关性(平均峰值速度:r = 0.81,P <.001;舒张峰值速度:r = 0.83,P <.001;速度储备:r = 0.56,P = .010)和狭窄(n = 7)(平均峰值速度:r = 0.83,P <.001;舒张期峰值速度:r = 0.78,P = .001;速度储备:r = 0.70,P = .078)移植物。结论:快速MR流动图提供了峰值速度和速度储备的非侵入性测量,在体外以及非狭窄和狭窄移植物中均与多普勒值密切相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号