首页> 外文期刊>Radiology >Breast lesion detection and classification: comparison of screen-film mammography and full-field digital mammography with soft-copy reading--observer performance study.
【24h】

Breast lesion detection and classification: comparison of screen-film mammography and full-field digital mammography with soft-copy reading--observer performance study.

机译:乳腺病变的检测和分类:将屏幕胶片乳腺X线摄影和全视野数字乳腺X线摄影与软拷贝阅读的比较-观察者表现研究。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: To retrospectively compare screen-film and full-field digital mammography with soft-copy interpretation for reader performance in detection and classification of breast lesions in women in a screening program. MATERIALS AND METHODS: Regional ethics committee approved the study; signed patient consents were obtained. Two-view mammograms were obtained with digital and screen-film systems at previous screening studies. Six readers interpreted images. Interpretation included Breast Imaging Reporting and Data System (BI-RADS) and five-level probability-of-malignancy scores. A case was one breast, with two standard views acquired with both screen-film mammography and digital mammography. The standard for an examination with normal findings was classification of normal (category 1) assigned by two independent readers; for cases with benign findings, the standard was benign results at diagnostic work-up in patients who were recalled. Cases with normal or benign findings that manifested as neither interval cancer nor as cancer at subsequent screening were considered the standard. All cancers were confirmed histologically. Images were interpreted by readers in two sessions 5 weeks apart; the same case was not seen twice in any session. Receiver operating characteristic (ROC) analysis and, for a given true-positive fraction, 2 x 2 table analysis and the McNemar test were used. For binary outcome, classification of BI-RADS category 3 or higher was defined as positive for cancer. RESULTS: Cases with proved findings (n = 232) were displayed: 46 with cancers, 88 with benign findings, and 98 with normal findings. ROC analysis for all readers and all cases revealed a higher area under ROC curve (A(z)) for digital mammography (0.916) than for screen-film mammography (0.887) (P = .22). Five of six readers had a higher performance rating with digital mammography; one of five demonstrated a significant difference in favor of digital mammography with A(z) values; two showed a significant difference in favor of digital mammography with ROC analysis for a given false-positive fraction (P = .01 and .03, respectively). For cases with cancer, digital mammography resulted in correct classification of an average of three additional cancers per reader. For digital versus screen-film mammography, 2 x 2 table analysis for cancers revealed a higher true-positive rate; for benign masses, a higher true-negative rate. Neither of these differences nor any others from analysis of subgroups between the modalities were significant. CONCLUSION: Digital mammography allowed correct classification of more breast cancers than did screen-film mammography. A(z) value was higher for digital mammography; this difference was not significant.
机译:目的:回顾性地比较屏幕胶片和全场数字化乳房X线摄影术与软拷贝解释在阅读程序中对女性乳腺病变的检测和分类中读者的表现。材料与方法:区域伦理委员会批准了该研究。已获得患者的签署同意书。在先前的筛选研究中,使用数字和银幕胶片系统获得了两幅乳房X光照片。六位读者解读图像。口译包括乳房成像报告和数据系统(BI-RADS)和五级恶性概率评分。一个案例是一只乳房,通过屏幕乳腺X线摄影和数字乳腺X线摄影获得了两个标准视图。具有正常发现的检查标准是由两个独立的读者分配的正常分类(类别1)。对于有良性发现的病例,标准是对召回患者进行诊断检查时的良性结果。具有正常或良性发现且既不表现为间隔癌也不表现为随后筛查的癌症的病例被视为标准。所有癌症均在组织学上证实。读者在相隔5周的两次会议中对图像进行了解释;在任何会话中两次都没有看到相同的案例。接收器工作特性(ROC)分析,对于给定的真-正分数,使用2 x 2表格分析和McNemar测试。对于二元结局,BI-RADS 3类或更高类别的分类被定义为癌症阳性。结果:显示出确诊结果的病例(n = 232):癌症46例,良性88例,正常98例。所有读者和所有病例的ROC分析显示,数字乳腺摄影(0.916)的ROC曲线下面积(A(z))比银幕乳腺摄影(0.887)高(P = .22)。六位读者中有五位在乳腺X线摄影方面的表现较高。五分之一的人表现出对数字乳腺X线照相术具有A(z)值的显着差异;对于给定的假阳性分数,两个人在使用ROC分析的数字化乳腺摄影方面表现出显着差异(分别为P = 0.01和.03)。对于患有癌症的病例,数字化乳腺X线摄影术可以正确分类每个阅读者平均另外三种癌症。对于数字乳腺X线和银幕乳腺X线摄影,癌症的2 x 2表格分析显示出较高的真实阳性率。对于良性人群,更高的真阴性率。这些差异以及这些方式之间亚组的分析均无显着差异。结论:数字化乳腺X线摄影术比筛查乳腺X线摄影术能够对更多的乳腺癌进行正确分类。数字乳腺摄影的A(z)值较高;这种差异并不明显。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号