PURPOSE: To evaluate differentiation of liver lesions at magnetic resonance (MR) imaging enhanced with Code-7227. MATERIALS AND METHODS: Thirty-five patients with 38 proved liver lesions (15 hemangiomas, 17 metastases, six hepatocellular carcinomas [HCCs]) underwent T1-weighted gradient-echo and T2-weighted fast-spin-echo MR imaging at 1.5 T before and after intravenous administration of Code-7227 (1.1 mg iron per kilogram of body weight). RESULTS: In hemangiomas, the mean contrast-to-noise ratio on precontrast and postcontrast images, respectively, increased from -4.51 +/- 4.7 (standard deviation) to 5.19 +/- 6.3 on T1-weighted images and decreased from 14.73 +/- 7.4 to 0.64 +/- 5.1 on T2-weighted images. In comparison, metastases remained hypointense to liver on T1-weighted images (from -5.77 +/- 5.9 to -7.8 +/- 6.8) and hyperintense on T2-weighted images (from 8.73 +/- 5.4 to 12.61 +/- 6.1). Although HCC enhanced more than metastases, they also remained hypointense to liver on T1-weighted images (from -4.87 +/- 6.1 to -1.79 +/- 5.7) and hyperintense on T2-weighted images (from 10.12 +/- 7.9 to 8.7 +/- 6.4). The degree of enhancement on T1-weighted images and of signal intensity drop on T2-weighted images were significantly lower in malignant liver masses than in hemangiomas (P < .001). CONCLUSION: Distinctly different enhancement patterns with Code-7227 helped accurate differentiation of liver lesions.
机译:目的:评估使用Code-7227增强磁共振(MR)成像对肝脏病变的分化。材料与方法:35例38例肝病证实患者(15例血管瘤,17例转移瘤,6例肝细胞癌[HCC])在1.5 T之前和之前分别进行了T1加权梯度回波和T2加权快速自旋回波MR成像。静脉注射Code-7227(每公斤体重1.1毫克铁)后。结果:在血管瘤中,对比前和对比后图像的平均对比噪声比分别从-4.51 +/- 4.7(标准差)增加到T1加权图像的5.19 +/- 6.3,而从14.73 + /降低-在T2加权图像上为7.4至0.64 +/- 5.1。相比之下,在T1加权图像上转移灶对肝脏仍然是低价的(从-5.77 +/- 5.9到-7.8 +/- 6.8),在T2加权图像上转移灶是高强度的(从8.73 +/- 5.4到12.61 +/- 6.1) 。尽管肝癌比转移灶增强的多,但在T1加权图像上它们仍对肝脏低敏感(从-4.87 +/- 6.1至-1.79 +/- 5.7),在T2加权图像上仍具有高强度(从10.12 +/- 7.9至8.7) +/- 6.4)。在恶性肝脏肿块中,T1加权图像的增强程度和T2加权图像的信号强度下降程度明显低于血管瘤(P <.001)。结论:Code-7227明显不同的增强方式有助于准确区分肝脏病变。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号