首页> 外文期刊>Radiology >Pediatric 99mTc-MDP bone SPECT with ordered subset expectation maximization iterative reconstruction with isotropic 3D resolution recovery.
【24h】

Pediatric 99mTc-MDP bone SPECT with ordered subset expectation maximization iterative reconstruction with isotropic 3D resolution recovery.

机译:小儿99mTc-MDP骨SPECT,具有各向同性3D分辨率恢复的有序子集期望最大化迭代重建。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To perform a preliminary evaluation of the image quality of pediatric technetium 99m ((99m)Tc) methylene diphosphonate (MDP) bone single photon emission computed tomography (SPECT) by using iterative reconstruction-ordered subset expectation maximization with three-dimensional resolution recovery (OSEM-3D)-and to assess whether any improvements with use of this technique could lead to a reduction in patient dose or a shortening in imaging time. MATERIALS AND METHODS: Institutional advisory board approval was obtained for this investigation. Fifty (99m)Tc-MDP SPECT studies of the spine were evaluated (36 female and 14 male patients; mean age, 15.5 years). Each study was acquired by using a dual-detector camera, with each detector rotating 360 degrees . By using filtered back projection (FBP) and OSEM-3D, images were reconstructed from data generated by both detectors. Likewise, OSEM-3D was used to reconstruct data from a single detector simulating half the administered radiopharmaceutical activity. Two nuclear medicine physicians, blinded to the patient data, reviewed the images for image quality in four different categories by using a four-point scale: artifacts (category 1), lesions (category 2), noise (category 3), and image sharpness (category 4). RESULTS: Compared with FBP, images reconstructed by using OSEM-3D with one or two detectors showed significant improvement in image quality with regard to lesion detection, noise level, and image sharpness (P < .02, .01, and .001, respectively). With OSEM-3D, no significant differences were observed when either one or two detectors were used. CONCLUSION: Improved image quality of skeletal SPECT with either a 50% reduction in radiation dose or a 50% reduction in acquisition time or combination of the two can be achieved by using OSEM-3D.
机译:目的:通过使用三维重构恢复的迭代重构排序子集期望最大化,对小儿tech 99m((99m)Tc)亚甲基二膦酸酯(MDP)骨单光子发射计算机断层扫描(SPECT)的图像质量进行初步评估(OSEM-3D)-并评估使用此技术的任何改进是否会导致患者剂量减少或成像时间缩短。材料与方法:这项研究获得了机构顾问委员会的批准。评估了50篇(99m)Tc-MDP SPECT研究(36例女性和14例男性;平均年龄:15.5岁)。每个研究都是通过使用双探测器摄像机进行的,每个探测器旋转360度。通过使用滤波反投影(FBP)和OSEM-3D,从两个探测器生成的数据中重建了图像。同样,OSEM-3D用于从单个检测器重建模拟一半给药放射性药物活性的数据。两名核医学医师对患者数据不了解,使用四点量表对图像进行了四种不同类别的图像质量检查:伪影(类别1),病变(类别2),噪声(类别3)和图像清晰度(类别4)。结果:与FBP相比,使用OSEM-3D与一或两个检测器重建的图像在病变检测,噪声水平和图像清晰度方面的图像质量显着提高(分别为P <.02,.01和.001) )。对于OSEM-3D,当使用一个或两个检测器时,没有观察到明显差异。结论:通过使用OSEM-3D可以提高骨骼SPECT的图像质量,将辐射剂量减少50%或将采集时间减少50%或将两者结合使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号