There is a well known tradeoff between image noise and image sharpness that is dependent on the number of iterations performed in ordered subset expectation maximization (OSEM) reconstruction of PET data. We aim to evaluate the impact of this tradeoff on the sensitivity and specificity of 18F-FDG PET for the diagnosis of temporal lobe epilepsy. A retrospective blinded reader study was performed on two OSEM reconstructions, using either 2 or 5 iterations, of 32 18F-FDG PET studies acquired at our institution for the diagnosis of temporal lobe epilepsy. The sensitivity and specificity of each reconstruction for identifying patients who were ultimately determined to be surgical candidates was assessed using an ROC analysis. The sensitivity of each reconstruction for identifying patients who showed clinical improvement following surgery was also assessed. Our results showed no significant difference between the two reconstructions studied for either the sensitivity and specificity of 18F-FDG PET for predicting surgical candidacy, or its sensitivity for predicting positive surgical outcomes. This implies that the number of iterations performed during OSEM reconstruction will have little impact on a reader based interpretation of 18F-FDG PET scans acquired for the diagnosis of temporal lobe epilepsy, and can be determined by physician and institutional preference.
机译:在图像噪声和图像清晰度之间存在众所周知的折衷,这取决于在PET数据的有序子集期望最大化(OSEM)重建中执行的迭代次数。我们旨在评估这种权衡对 18 F-FDG PET诊断颞叶癫痫的敏感性和特异性的影响。回顾性盲读者研究是对2项OSEM重建进行的,采用2或5次迭代,对我院用于诊断颞叶癫痫的32项 18 F-FDG PET研究进行了研究。使用ROC分析评估了每次重建用于识别最终确定为手术候选患者的敏感性和特异性。还评估了每种重建方法对识别出术后临床表现有所改善的患者的敏感性。我们的结果表明,在 18 F-FDG PET预测手术候选者的敏感性和特异性,或预测阳性手术结果的敏感性方面,研究的两种重建方法之间没有显着差异。这意味着在OSEM重建过程中执行的迭代次数将不会对基于阅读器的用于诊断颞叶癫痫的 18 F-FDG PET扫描的解释产生影响,并且可由医师和制度偏好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号