Validation of the internal reference technique for microdialysis measurements of interstitial histamine in the rat

机译:内部参考技术在大鼠间质组胺微透析测量中的验证

获取原文
获取原文并翻译 | 示例

摘要

The internal reference technique (IRT) was compared with the no net flux method (NFM) as a microdialysis calibration technique for sampling of interstitial histamine in the rat. Microdialysis catheters (polyacrylonitrile, 50 kD cut off) were inserted in liver, muscle, subcutaneous tissue and in an induced adenocarcinoma. Estimated relative recovery with IRT ranged from 23 +- 2% in liver to 30 +- 3% in subcutaneous tissue with and without tumor (p < 0.05). By using the NFM-technique we found similar recovery as compared to the IRT in all tissues studied. Interstitial histamine was up to 3-fold higher than the mean plasma histamine concentration (54 +- 2 nmol/l). Subcutaneous tissue (177 +- 39 nmol/l) and subcutaneous tumor (165 +- 29 nmol/l) exhibited high histamine while liver (65 +- 14 nmol/l) and liver tumor (75 +- 7 nmol/l) had low interstitial histamine concentrations. In conclusion, the IRT was validated against the NFM as a rapid method for histamine measurements in situ in the rat.
机译:将内部参考技术(IRT)与无净通量方法(NFM)作为用于大鼠间质组胺采样的微透析校准技术进行了比较。将微透析导管(聚丙烯腈,截断50 kD)插入肝,肌肉,皮下组织和诱发的腺癌中。 IRT估计的相对恢复范围在有或没有肿瘤的肝脏中为23±2%,在皮下组织中为30±3%(p <0.05)。通过使用NFM技术,我们发现在所有研究的组织中,与IRT相比,其恢复情况相似。间质组胺比平均血浆组胺浓度(54±2 nmol / l)高3倍。皮下组织(177 +-39 nmol / l)和皮下肿瘤(165 +-29 nmol / l)表现出较高的组胺水平,而肝脏(65 +-14 nmol / l)和肝肿瘤(75 +-7 nmol / l)具有较高的组胺水平。间质组胺浓度低。总而言之,IRT已针对NFM进行了验证,可作为大鼠中原位测量组胺的快速方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号