According to the requirement of the calibration in minimally invasive blood glucose monitoring, a method based on microdialysis was presented to monitor glucose level in interstitial fluid continuously. An experimental system simulating the continuous change of glucose concentration in vivo was built. The influences on recovery of microdialysis caused by flow rate, glucose concentration, and temperature etc. were studied. The results led to the conclusion that the recovery fell by 71.7% when perfusion rate increased from 0.3 μL/min to 3.0 μL/min, while the different concentrations of glucose solutions scarcely contribute to the recovery instead, and the temperatures from 25 to 58 ℃ caused the recovery to increase by 34.6%.
机译:根据微创血糖监测中标定的要求,提出了一种基于微透析的连续监测组织液中葡萄糖水平的方法。建立了模拟体内葡萄糖浓度连续变化的实验系统。研究了流速,葡萄糖浓度和温度等因素对微透析恢复的影响。结果表明,当灌注速率从0.3μL/ min增加到3.0μL/ min时,回收率下降了71.7%,而不同浓度的葡萄糖溶液几乎没有贡献,而温度从25到58℃导致回收率提高了34.6%。

著录项

  • 来源
  • 会议地点 San Francisco CA(US)
  • 作者单位

    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, 300072, China;

    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, 300072, China;

    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, 300072, China;

    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, 300072, China;

    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, 300072, China;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    interstitial fluid; continuous glucose monitoring; microdialysis; calibration;

    机译:间隙液连续葡萄糖监测;微透析校准;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号