To quantify noninvasively myocardial blood flow (MBF) and MBF reserve in isoflurane-anesthetized rats using the Look-Locker flow-alternating inversion recovery gradient-echo arterial spin labeling technique (LLFAIRGE-ASL), and to compare the results with the fluorescent microsphere (FM) technique. Male Wistar rats (weight=200-240g, n=21) were anesthetized with 2.0% isoflurane. Hemodynamic parameters were recorded. In seven rats, MBF was assessed on a Bruker Biospec 4.7T MR system using an ECG- and respiration-gated LLFAIRGE-ASL (pixel size=234×468μm~2, TE=1.52ms) at rest and during adenosine infusion (140μg/kg/min). A mixture of 200 000 FM was injected into a second group of rats at rest and during adenosine infusion (n=7 each), under similar physiologic conditions. Hearts and skeletal muscle samples were processed for fluorescence spectroscopy. Two-tailed unpaired, paired Student's t-test and ANOVAwere used to compare groups. MBF measured with LLFAIRGE-ASL was 5.2±1.0mL/g/min at rest and 13.3±3.0mL/g/min during adenosine infusion. Results obtained with fluorescent microspheres yielded 5.9±2.3mL/g/min (nonsignificant vs. LLFAIRGE-ASL, p=0.9) at rest and 13.1±2.1mL/g/min (nonsignificant vs. LLFAIRGE-ASL, p=0.4) during adenosine infusion. Myocardial blood flow reserve measured using LLFAIRGE-ASL and FM were not significantly different (2.5±0.6 vs. 2.4±0.9, respectively; p=0.8). Hemodynamic parameters during the experiments were not different between the groups. The myocardial blood flow reserve determined under isoflurane anesthesia was 2.5±0.6, which was not different from the value obtained with FM. LLFAIRGE-ASL provided MBF maps with high spatial resolution in rats under isoflurane anesthesia. LLFAIRGE-ASL is a noninvasive measure to assess myocardial blood flow reserve and provides an interesting tool for cardiovascular research. Copyright ? 2011 John Wiley & Sons, Ltd. This study shows that Look-Locker flow-sensitive alternating inversion recovery gradient-echo (LLFAIRGE-ASL) allows quantification of myocardial blood flow (MBF) reserve in freely breathing rats under isoflurane. Using both techniques LLFAIRGE and fluorescent microspheres (FM), and under similar physiologic conditions, we measured the MBF reserve to be approximately 2.5. There were no significant differences in MBF measures obtained with LLFAIRGE and FM, at rest and under adenosine.
机译:若要使用Look-Locker交替流反转反转恢复梯度回波动脉自旋标记技术(LLFAIRGE-ASL)量化异氟烷麻醉大鼠的无创心肌血流量(MBF)和MBF储备,并将结果与​​荧光微球进行比较FM)技术。用2.0%异氟烷麻醉雄性Wistar大鼠(体重= 200-240g,n = 21)。记录血流动力学参数。在7只大鼠中,在静息状态和腺苷输注(140μg/ min)时使用心电图和呼吸门控LLFAIRGE-ASL(像素大小= 234×468μm〜2,TE = 1.52ms)在Bruker Biospec 4.7T MR系统上评估MBF。公斤/分钟)。在静止和腺苷输注过程中(每组n = 7),在相似的生理条件下,将200 000 FM的混合物注射到第二组大鼠中。对心脏和骨骼肌样品进行荧光光谱处理。使用两尾未配对,成对的学生t检验和ANOVA进行比较。用LLFAIRGE-ASL测定的MBF在静息时为5.2±1.0mL / g / min,在腺苷输注时为13.3±3.0mL / g / min。荧光微球在静止时产生的结果为5.9±2.3mL / g / min(相对于LLFAIRGE-ASL,无显着性,p = 0.9),在静止期间为13.1±2.1mL / g / min(相对于LLFAIRGE-ASL,无显着性,p = 0.4)。腺苷输注。使用LLFAIRGE-ASL和FM测量的心肌血流储备没有显着差异(分别为2.5±0.6和2.4±0.9; p = 0.8)。两组之间的血流动力学参数无差异。异氟烷麻醉下测得的心肌血流储备为2.5±0.6,与FM获得的值无差异。 LLFAIRGE-ASL为异氟烷麻醉下的大鼠提供了具有高空间分辨率的MBF图。 LLFAIRGE-ASL是一种评估心肌血流储备的非侵入性措施,为心血管研究提供了一种有趣的工具。版权? 2011年John Wiley&Sons,Ltd.。这项研究表明,Look-Locker流量敏感的交替反转恢复梯度回波(LLFAIRGE-ASL)可以量化异氟醚下自由呼吸大鼠的心肌血流(MBF)储备。使用LLFAIRGE和荧光微球(FM)两种技术,并在相似的生理条件下,我们测得的MBF储备约为2.5。用LLFAIRGE和FM进行的MBF测量在静止和腺苷下均无显着差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号