首页> 外文期刊>ifac papersonline >An Intraoperative Glucose Control Benchmark for Formal Verification
【24h】

An Intraoperative Glucose Control Benchmark for Formal Verification

机译:用于形式验证的术中血糖控制基准

获取原文
获取原文并翻译 | 示例

摘要

Diabetes associated complications are affecting an increasingly large population of hospitalized patients. Since glucose physiology is significantly impacted by patient-specific parameters, it is critical to verify that a clinical glucose control protocol is safe across a wide patient population. A safe protocol should not drive the glucose level into dangerous low (hypoglycemia) or high (hyperglycemia) ranges. Verification of glucose controllers is challenging due to the high-dimensional, non-linear glucose physiological models which contain both unobservable states and unmeasurable patient-specific parameters. This paper presents a hybrid system model of a closed-loop physiological system that includes an existing FDA-accepted high-fidelity physiological model tailored to intraoperative settings and a validated improvement to a clinical glucose control protocol for diabetic cardiac surgery patients. We propose the closed-loop model as a physiological system benchmark for verification and present our initial results on verifying the system using the SMT-based hybrid system verification tool dReach.
机译:糖尿病相关并发症正在影响越来越多的住院患者。由于葡萄糖生理学受到患者特定参数的显着影响,因此验证临床血糖控制方案在广泛的患者群体中是否安全至关重要。安全方案不应将血糖水平降低到危险的低血糖(低血糖)或高血糖(高血糖)范围。由于高维、非线性葡萄糖生理模型包含不可观察的状态和无法测量的患者特定参数,因此葡萄糖控制器的验证具有挑战性。本文介绍了一个闭环生理系统的混合系统模型,其中包括一个现有的 FDA 认可的针对术中环境量身定制的高保真生理模型,以及对糖尿病心脏手术患者临床血糖控制方案的验证改进。我们提出闭环模型作为生理系统验证基准,并展示了我们使用基于SMT的混合系统验证工具dReach验证系统的初步结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号