首页> 外文期刊>Neurosurgery >Biomechanical Comparison of Costotransverse Process Screw Fixation and Pedicle Screw Fixation of the Upper Thoracic Spine
【24h】

Biomechanical Comparison of Costotransverse Process Screw Fixation and Pedicle Screw Fixation of the Upper Thoracic Spine

机译:胸椎上棘突横突固定和椎弓根螺钉固定的生物力学比较

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To compare the biomechanlcs of costotransverse process screw fixation with those of pedicle screw fixation in a cadaveric model of the upper thoracic spine. METHODS:Ten human thoracic spines were instrumented across theT3-T4 segment with costotransverse and pedicle screws. Nonconstraining pure moments (maximum, 6.0 Nm) were applied to induce flexion, extension, lateral bending, and axial rotation. The range of motion, lax zone, and stiff zone were determined in each specimen in the normal state, after 3-column destabilization, and after instrumentation. After flexibility testing was completed, axial screw pull-out strength was assessed.RESULTS: In all directions of loading, both fixation techniques significantly decreased lax zone and range of motion at T3-T4 compared with the destabilized state (P < .001). During all loading modes except lateral bending, pedicle screw fixation allowed significantly less range of motion than costotransverse screw fixation. Pedicle screws provided 62% greater resistance to axial pull-out than costotransverse screws.CONCLUSION: The costotransverse screw technique seems to provide only moderately stiff fixation of the destabilized thoracic spine. Pedicle screw fixation seems to have more favorable biomechanical properties. These data suggest that the costotransverse process construct is better used as a salvage procedure rather than as a primary fixation strategy.
机译:目的:比较上胸椎尸体模型中肋横突螺钉固定与椎弓根螺钉固定的生物力学。方法:用肋横突和椎弓根螺钉在十个T3-T4节段上穿刺十个人的胸椎。施加无约束的纯力矩(最大6.0 Nm)以引起弯曲,伸展,横向弯曲和轴向旋转。在正常状态下,三柱去稳定后和仪器安装后,确定每个样品的运动范围,松弛区和刚性区。结果:在所有载荷方向上,与不稳定状态相比,两种固定技术均显着减小了T3-T4处的松弛区和运动范围(P <.001)。在所有加载模式中,除横向弯曲外,椎弓根螺钉固定的运动范围均比肋横螺钉固定小。椎弓根螺钉的抗轴向拔出力比肋横螺钉高62%。结论:肋横螺钉技术似乎只能对不稳定的胸椎提供中等强度的固定。椎弓根螺钉固定似乎具有更有利的生物力学性能。这些数据表明,肋横突结构更好地用作打捞程序,而不是主要的固定策略。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号