首页> 外文期刊>Nephrology nursing journal: journal of the American Nephrology Nurses’ Association >A continuous quality improvement project to decrease hemodialysis catheter infections in pediatric patients: use of a closed luer-lock access cap.
【24h】

A continuous quality improvement project to decrease hemodialysis catheter infections in pediatric patients: use of a closed luer-lock access cap.

机译:一项持续的质量改进项目,以减少小儿患者的血液透析导管感染:使用密闭的鲁尔锁通道盖。

获取原文
获取原文并翻译 | 示例
           

摘要

Catheter infections are a significant problem in pediatric hemodialysis. To reduce infection rates, the use of closed luer-lock access connectors, which create a mechanically and microbiogically closed system while allowing unobstructed blood flow, was implemented Infection rates fell from 7.8 infections per 1000 patient days to 3.65 infections per 1000 patient days after the switch to the closed connector (t = 0.04). The adoption of a closed connector system appeared to produce a significant reduction in bloodstream infections.
机译:导管感染是小儿血液透析中的重要问题。为了降低感染率,实施了封闭的鲁尔锁接入连接器,该连接器在机械和微生物封闭的情况下建立了封闭的血液流动,同时又实现了机械和微生物封闭系统的感染。切换到闭合的连接器(t = 0.04)。采用封闭连接器系统似乎可以显着减少血液感染。