首页> 外文期刊>Knee surgery, sports traumatology, arthroscopy: official journal of the ESSKA >Three different cruciate-sacrificing TKA designs: minor intraoperative kinematic differences and negligible clinical differences
【24h】

Three different cruciate-sacrificing TKA designs: minor intraoperative kinematic differences and negligible clinical differences

机译:三种不同的牺牲性TKA设计:术中轻微运动学差异和可忽略的临床差异

获取原文
获取原文并翻译 | 示例
           

摘要

Methods: Three groups of patients, divided according to implant design, were analysed retrospectively. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during: passive range of motion and anterior drawer test at 90° flexion. WOMAC, KSS and SF36 scores were collected pre-operatively and at 2-year follow-up.Results: There are no differences in kinematic or clinical performance of the three implants, except for the antero-posterior translation during stress test in flexion: only Cohort B had comparable pre- and post-operative laxity test values (p < 0.001). All three TKA designs allowed to maintain pre-operative tibial rotation pattern through all range of knee flexion. All clinical scores of the three patient cohorts were significantly improved post-operatively compared to the pre-operative values (p < 0.001). Moreover, we found no differences among post-operative results of the three designs.Conclusion: Despite design variations, mobile-bearing PCL-sacrificing TKA reproduces femoral rollback and screw-home with little or no difference in clinical or functional scores at a follow-up of 2 years.Level of evidence: III.Purpose: The goal of this study was to compare three types of mobile-bearing posterior cruciate ligament (PCL)-sacrificing TKA. The hypothesis was that the three designs provide differences in flexion stability and femoral rollback and improved clinical score at 2-year follow-up.
机译:方法:回顾性分析三组患者,根据种植体设计进行分组。所有操作均由非基于图像的导航系统指导,该系统记录以下情况下的原始和植入膝盖的股和胫骨相对位置:被动运动范围和90°屈曲的前抽屉测试。术前和随访2年,收集WOMAC,KSS和SF36评分。结果:三种植入物的运动学或临床表现均无差异,除了屈曲压力测试中的前后翻译:仅队列B的术前和术后松弛测试值相当(p <0.001)。所有这三种TKA设计均允许在所有膝盖屈曲范围内保持术前胫骨旋转模式。与术前相比,这三个患者队列的所有临床评分均得到了显着改善(p <0.001)。此外,我们发现这三种设计的术后结果之间没有差异。结论:尽管设计有所不同,但移动支承的PCL牺牲性TKA能够再现股骨后倾和螺钉入路,临床或功能评分在随访时几乎没有差异。最多2年。证据水平:III。目的:这项研究的目的是比较三种类型的可移动性承载后交叉韧带(PCL)的TKA。假设是,这两种设计在2年的随访中提供了屈曲稳定性和股骨回滚的差异,并改善了临床评分。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号