The fundamental quantities in the depth sensing hardness test are force and displacement. The penetration depth used for the calculation of a certain hardness parameter (for instance HU, Eq. (1)) makes it necessary to determine the contact point. As shown in the paper, fitting of the force-displacement curve, F(h), by a second order polynomial and extrapolating to F = 0 is not always the right way to achieve a sufficiently small uncertainty of depth. The feature of that procedure is analysed by a simple mathematical model. In dependence of the testing force, the scatter of the experimental data, and the required limit of depth uncertainty, a profound selection of the fitting range, the fitting function, and the extrapolation function should be done.
机译:深度感测硬度测试的基本量是力和位移。用于计算某个硬度参数(例如HU,等式(1))的穿透深度使得必须确定接触点。如本文所示,力-位移曲线F(h)通过二阶多项式拟合并外推至F = 0并非始终是获得足够小的深度不确定性的正确方法。该过程的特征通过一个简单的数学模型进行分析。根据测试力,实验数据的分散性和所需的深度不确定性极限,应进行深度选择拟合范围,拟合函数和外推函数。