We present measurements on a pulse-driven ac Josephson voltage standard (ACJVS) for frequencies up to 1 MHz. By automating our setup we were able to perform a systematic study of the frequency dependence of the ACJVS output. We show that the error caused by the voltage leads is the major error source when measuring at frequencies up to 1 MHz. The squared frequency dependence of the error, which is caused by a resonance in the circuit, allows us to make a correction that results in an uncertainty on the μV V~(-1) level for frequencies up to at least 20 kHz.
机译:我们介绍了在高达1 MHz频率的脉冲驱动交流约瑟夫森电压标准(ACJVS)上的测量结果。通过自动化我们的设置,我们能够对ACJVS输出的​​频率依赖性进行系统的研究。我们表明,在高达1 MHz的频率下进行测量时,电压引线引起的误差是主要的误差源。由电路中的谐振引起的误差的平方频率依赖性,使我们能够进行校正,从而导致在至少20 kHz的频率下μVV〜(-1)电平具有不确定性。