首页> 外文期刊>Methods of information in medicine >Robust detection of sleep apnea from holter ECGs: Joint assessment of modulations in QRS amplitude and respiratory myogram interference
【24h】

Robust detection of sleep apnea from holter ECGs: Joint assessment of modulations in QRS amplitude and respiratory myogram interference

机译:强大的动态心电图检测睡眠呼吸暂停:联合评估QRS振幅和呼吸肌电图干扰的调制

获取原文
获取原文并翻译 | 示例

摘要

Introduction: This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems". Objectives: Detect presence of sleep-related breathing disorders (SRBD) in epochs of 1 min by signal analysis of Holter ECG recordings. Methods: In 121 patients, 140 synchronized polysomnograms (PSGs) and 8-channel Holter ECGs were recorded. The only excluded condition was persistent arrhythmias. Respiratory events as scored from the PSGs were mapped to a 1 min grid and served as reference for ECG-based detection. More-over, 69/70 recordings of the Physionet Sleep Apnea ECG Database (PADB) were included. We performed receiver operating characteristics analysis of a single, novel time-domain feature, the joint local similarity index (jLSI). Based on cross-correlation, the jLSI quantifies the time-locked occurrence of characteristic low-frequency (LF) modulations in ECG respiratory myogram interference (RMI), QRS amplitude (QRSA) and heart rate. Results: Joint oscillations in QRSA, RMI and the envelope of RMI identified positive epochs with a sensitivity of 0.855 (PADB: 0.873) and a specificity of 0.86 (PADB: 0.88). Inclusion of heart rate did not improve detection accuracy. Conclusions: Joint occurrence of LF-modu-lations in QRSA and RMI is a characteristic feature of SRBD that is robustly quantified by the jLSI and permits reliable and reproducible detection of sleep apnea in very hetero -geneous settings.
机译:简介:本文是“生物信号解释:研究心血管和呼吸系统的先进方法”的医学信息方法重点主题的一部分。目的:通过动态心电图心电图记录的信号分析,在1分钟内检测出与睡眠有关的呼吸障碍(SRBD)。方法:在121例患者中,记录了140幅同步多导睡眠图(PSG)和8通道动态心电图。唯一排除的疾病是持续性心律不齐。将来自PSG的呼吸事件映射到1分钟的网格,并作为基于ECG的检测的参考。此外,还包括Physionet睡眠呼吸暂停ECG数据库(PADB)的69/70记录。我们对单个新颖的时域特征,联合局部相似性指数(jLSI)进行了接收机工作特性分析。基于互相关,jLSI量化了ECG呼吸肌象干扰(RMI),QRS振幅(QRSA)和心率中特征性低频(LF)调制的时间锁定现象。结果:QRSA,RMI和RMI包膜的联合振荡确定了阳性时期,敏感性为0.855(PADB:0.873),特异性为0.86(PADB:0.88)。包含心率并不能提高检测准确性。结论:QRSA和RMI中的LF调节共同出现是SRBD的一个特征,jLSI对其进行了可靠的定量分析,并允许在非常异类的环境中可靠且可重复地检测到睡眠呼吸暂停。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号