Purpose: The purpose of the present work was to develop and validate a method of retrospectively estimating the dose-area product (DAP) of a chest tomosynthesis examination performed using the VolumeRAD system (GE Healthcare, Chalfont St. Giles, UK) from digital imaging and communications in medicine (DICOM) data available in the scout image.Methods: DICOM data were retrieved for 20 patients undergoing chest tomosynthesis using VolumeRAD. Using information about how the exposure parameters for the tomosynthesis examination are determined by the scout image, a correction factor for the adjustment in field size with projection angle was determined. The correction factor was used to estimate the DAP for 20 additional chest tomosynthesis examinations from DICOM data available in the scout images, which was compared with the actual DAP registered for the projection radiographs acquired during the tomosynthesis examination.Results: A field size correction factor of 0.935 was determined. Applying the developed method using this factor, the average difference between the estimated DAP and the actual DAP was 0.2%, with a standard deviation of 0.8%. However, the difference was not normally distributed and the maximum error was only 1.0%. The validity and reliability of the presented method were thus very high.Conclusions: A method to estimate the DAP of a chest tomosynthesis examination performed using the VolumeRAD system from DICOM data in the scout image was developed and validated. As the scout image normally is the only image connected to the tomosynthesis examination stored in the picture archiving and communication system (PACS) containing dose data, the method may be of value for retrospectively estimating patient dose in clinical use of chest tomosynthesis.
机译:目的:本工作的目的是开发和验证一种方法,该方法可根据数字成像回顾性地评估使用VolumeRAD系统(GE Healthcare,Chalfont St. Giles,英国)进行的胸部断层合成检查的剂量面积乘积(DAP)。方法:通过VolumeRAD检索20例行胸部断层合成的患者的DICOM数据。使用有关如何通过侦查图像确定层析成像检查的曝光参数的信息,确定用于根据投影角度调整视场大小的校正因子。校正因子用于从侦察员图像中获得的DICOM数据估计另外20项胸部X线断层摄影检查的DAP,并将其与在X线断层摄影检查中获取的投影放射线照片注册的实际DAP进行比较。测定为0.935。应用使用此因子的改进方法,估计DAP与实际DAP之间的平均差为0.2%,标准偏差为0.8%。但是,差异不是正态分布的,最大误差仅为1.0%。结论:结论:开发并验证了利用VolumeRAD系统从侦察图像中的DICOM数据估算胸部断层综合检查DAP的方法。由于侦察图像通常是存储在包含剂量数据的图片归档和通信系统(PACS)中的与断层合成检查相关的唯一图像,因此该方法对于在胸部断层合成的临床应用中回顾性评估患者剂量可能具有价值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号