首页> 外文期刊>Medical Physics >Design and evaluation of a methodology to perform personalized visual biofeedback for reducing respiratory amplitude in radiation treatment.
【24h】

Design and evaluation of a methodology to perform personalized visual biofeedback for reducing respiratory amplitude in radiation treatment.

机译:设计和评估执行个性化视觉生物反馈以减少放射治疗中呼吸幅度的方法。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A methodology to perform personalized visual biofeedback aimed to the reduction of respiratory amplitude is here proposed. A custom-made software allows to adapt the biofeedback parameters to a patient's respiratory pattern by calculating a limiting range for respiratory amplitude obtained from data acquired during free breathing. The proposed methodology has been tested on ten healthy volunteers and on five lung cancer patients undergoing radiotherapy treatment. The protocol for volunteers consisted of 3 min of data acquisition during the subject's free breathing, 2 min of visual biofeedback within the limits, and 3 min of free breathing. The patients' free breathing was acquired in 3 min and the visual biofeedback performed during all the sessions of the radiotherapy treatment, i.e., an average of eight sessions and an average total treatment time of 2000 s each patient. All the volunteers and three patients of the five found the protocol comfortable. The settlement time needed for considering the limiting range stabilized during free breathing has been calculated as 120 +/- 10 s (p < 0.05). During visual biofeedback the baseline shift was removed and the average respiratory amplitude was reduced by about 40% for all the subjects. The variability of the breathing amplitude remained unaltered during biofeedback. Eight volunteers and three patients remained within the limiting range for more than 90% of the biofeedback period; all subjects remained within the limiting range for more than 80% of the biofeedback period. During the biofeedback period both groups, volunteers and patients, showed a significant increase in breathing frequency which was mostly doubled. Patients with shallow breathing performed comfortably the biofeedback.
机译:本文提出了一种旨在实现个性化视觉生物反馈的方法,旨在降低呼吸幅度。通过计算自由呼吸过程中获取的数据所获得的呼吸幅度极限范围,定制软件可以使生物反馈参数适应患者的呼吸模式。建议的方法已在十名健康志愿者和五名接受放射治疗的肺癌患者中进行了测试。志愿者的方案包括受试者自由呼吸期间3分钟的数据采集,极限范围内2分钟的视觉生物反馈和3分钟的自由呼吸。在3分钟内获得患者的自由呼吸,并在放疗的所有疗程中进行视觉生物反馈,即平均每个患者进行8疗程,平均总治疗时间为2000 s。所有志愿者和五名患者中的三名患者都觉得该方案很舒适。考虑到自由呼吸期间稳定的极限范围所需的稳定时间已计算为120 +/- 10 s(p <0.05)。在视觉生物反馈过程中,消除了所有患者的基线偏移,平均呼吸幅度降低了约40%。在生物反馈过程中,呼吸幅度的可变性保持不变。 8位志愿者和3位患者在生物反馈期间的90%以上仍处于限制范围内;所有受试者在生物反馈期的80%以上都保持在限制范围内。在生物反馈期间,无论是志愿者还是患者,两组都显示出呼吸频率的显着增加,大部分都增加了一倍。呼吸浅的患者进行了生物反馈舒适。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号