Stereotactic body radiotherapy (SBRT) can be used to treat small lesions in the chest. A vacuum-based immobilization system is used in our clinic for SBRT, and a motion envelope is used in treatment planning. The purpose of this study is to automatically derive motion envelopes using deformable image registration of 4D-CT images, and to assess the effect of abdominal pressure on the motion envelopes. 4D-CT scans at ten phases were acquired prior to treatment for both free and restricted breathing using a vacuum-based immobilization system that includes an abdominal pressure pillow. To study the stability of the motion envelope over the course of treatment, a mid-treatment 4D-CT scan was obtained after delivery of the third fraction for two patients. The planning target volume excluding breathing motion (PTV(ex)) was defined on the image set at full exhalation phase and transformed into all other phases using displacement maps from deformable image registration. The motion envelope was obtained as the union of PTV(ex) masks of all phases. The ratios of the motion envelope to PTV(ex) volume ranged from 1.3 to 2.5. When pressure was applied, the ratios were reduced by as much as 29% compared to free breathing for some patients, but increased by up to 9% for others. The abdominal pressure pillow has more motion restriction effects on the anterior/inferior region of the lung. For one of the two patients for whom the 4D-CT scan was repeated at mid-treatment, the motion envelope was reproducible. However, for the other patient the tumor location and lung motion pattern significantly changed due to changes in the anatomy surrounding the tumor during the course of treatment, indicating that an image-guided approach to SBRT may increase the efficacy of this treatment.
机译:立体定向放射疗法(SBRT)可用于治疗胸部的小病变。我们的诊所将基于真空的固定系统用于SBRT,并在治疗计划中使用了运动包络线。这项研究的目的是使用4D-CT图像的可变形图像配准自动得出运动包络,并评估腹压对运动包络的影响。使用包括腹部压力枕的基于真空的固定系统,在治疗自由呼吸和受限呼吸之前,需要在十个阶段进行4D-CT扫描。为了研究运动包膜在治疗过程中的稳定性,在为两名患者提供第三部分后,进行了治疗中的4D-CT扫描。在完全呼气阶段在图像集上定义计划目标体积(不包括呼吸运动)(PTV(ex)),并使用来自可变形图像配准的位移图将其转换为所有其他阶段。运动包络是作为所有阶段的PTV(ex)蒙版的并集而获得的。运动包络线与PTV(ex)体积的比率范围为1.3到2.5。当施加压力时,与某些患者的自由呼吸相比,该比率降低了多达29%,而对于其他患者,则增加了高达9%。腹压枕对肺部的前/下区域具有更多的运动限制作用。对于在治疗中期重复进行4D-CT扫描的两名患者之一,其运动包膜是可再现的。但是,对于其他患者,由于在治疗过程中肿瘤周围的解剖结构发生变化,因此肿瘤的位置和肺运动模式发生了显着变化,这表明以图像为指导的SBRT方法可能会提高这种治疗的疗效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号