Digital tomosynthesis of hand joints for arthritis assessment.

机译:用于关节炎评估的手关节数字断层合成。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The two principal forms of hand arthritis, rheumatoid arthritis (RA) and osteoarthritis (OA) have large clinical and economic costs. Radiography has been shown to be a useful tool to assess the condition of the disease. A hand radiograph, however, is a two-dimensional projection of a three-dimensional object. In this report we present the results of a study that applied digital tomosynthesis to hand radiography in order to extract three-dimensional outcome measures that should be more sensitive to arthritis progression. The study was performed using simulated projection radiographs created using micro computed tomography (microCT) and a set of five dry-bone hand skeletons. These simulated projection images were then reconstructed into tomographic slices using the matrix inversion tomosynthesis (MITS) algorithm. The accuracy of the tomosynthesis reconstruction was evaluated by comparing the reconstructed images to a gold standard created using the microCT data. A parameter from image registration science, normalized mutual information, provided a quantifiable figure of merit. This study examined the effects of source displacement, number of reconstructed planes, number of acquisitions, noise added to the gray scale images, and errors in the location of a fiducial marker. We also optimized the reconstruction as a function of two variables k and alpha, that controlled the mixing of MITS with conventional shift-and-add tomosynthesis. A study using hand delineated joint margins demonstrated that MITS images provided a better measurement of average joint space width. We found good agreement between the MITS slices and the true planes. Both joint margins and trabecular structure were visible and the reconstructed slices showed additional structures not visible with the standard projection image. Using hand-delineated joint margins we compared the average joint space width of the gold standard slices to the MITS and projection images. A root-mean square deviation (RMSD), calculated for this comparison, gave RMSDproj = 0.18 mm and RMSDMITS = 0.14 mm for the projection and MITS images, respectively. We have demonstrated the potential of digital tomosynthesis for imaging of the hand to assess arthritic changes. We have also developed a methodology that can be used to optimize the technique and have studied the issues that will control the feasibility of clinical implementation.
机译:手关节炎的两种主要形式,类风湿性关节炎(RA)和骨关节炎(OA)具有巨大的临床和经济成本。放射线照相术已被证明是评估疾病状况的有用工具。然而,手部放射线照片是三维物体的二维投影。在本报告中,我们介绍了一项将数字断层合成技术应用于手部X线照相术的研究结果,以提取对关节炎进展更为敏感的三维结果量度。这项研究是使用模拟投影射线照相术进行的,该射线照相照相术是使用微型计算机断层扫描(microCT)和一组五个干骨手骨骼制作的。然后,使用矩阵反转断层合成(MITS)算法将这些模拟的投影图像重建为断层摄影切片。通过将重建图像与使用microCT数据创建的黄金标准进行比较,评估断层合成重建的准确性。来自图像配准科学的参数,标准化的互信息,提供了可量化的品质因数。这项研究检查了源位移,重建平面的数量,采集数量,添加到灰度图像中的噪声以及基准标记位置的误差的影响。我们还优化了作为两个变量k和alpha的函数的重构,该重构控制了MITS与常规移位加法层析合成的混合。使用手工绘制的关节边缘的研究表明,MITS图像可以更好地测量平均关节间隙宽度。我们在MITS切片和真实平面之间找到​​了很好的一致性。关节边缘和小梁结构均可见,重建的切片显示标准投影图像不可见的其他结构。我们使用手工描绘的联合边距,将金标准切片的平均联合空间宽度与MITS和投影图像进行了比较。为进行此比较而计算出的均方根偏差(RMSD)分别使投影图像和MITS的RMSDproj = 0.18 mm和RMSDMITS = 0.14 mm。我们已经展示了数字断层合成技术在手部成像以评估关节炎变化方面的潜力。我们还开发了可用于优化技术的方法,并研究了将控制临床实施可行性的问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号