A new accelerometer, the Kenz Lifecorder EX (LC; Suzuken Co. Ltd, Nagoya, Japan), offers promise as a feasible monitor alternative to the commonly used Actigraph (AG: Actigraph LLC, Fort Walton Beach, FL). PURPOSE: This study compared the LC and AG accelerometers and the Yamax SW-200 pedometer (DW) under free-living conditions with regard to children's steps taken and time in light-intensity physical activity (PA) and moderate to vigorous PA (MVPA). METHODS: Participants (N=31, age=10.2 +/- 0.4 yr) wore LC, AG, and DW monitors from arrival at school (7:45 a.m.) until they went to bed. Time in light and MVPA intensities were calculated using two separate intensity classifications for the LC (LC_4 and LC_5) and four classifications for the AG (AG_Treuth, AG_Puyau, AG_Trost, and AG_Freedson). Both accelerometers provided steps as outputs. DW steps were self-recorded. Repeated-measures ANOVA was used to assess overlapping monitor outputs. RESULTS: There was no difference between DW and LC steps (Delta=200 steps), but a nonsignificant trend was observed in the pairwise comparison between DW and AG steps (Delta=1001 steps, P=0.058). AG detected significantly greater steps than the LC (Delta=801 steps, P=0.001). Estimates of light-intensity activity minutes ranged from a low of 75.6 +/- 18.4 min (LC_4) to a high of 309 +/- 69.2 min (AG_Treuth). Estimates of MVPA minutes ranged from a low of 25.9 +/- 9.4 min (LC_5) to a high of 112.2 +/- 34.5 min (AG_Freedson). No significant differences in MVPA were seen between LC_5 and AG_Treuth (Delta=4.9 min) or AG_Puyau (Delta=1.7 min). CONCLUSION: The LC detected a comparable number of steps as the DW but significantly fewer steps than the AG in children. Current results indicate that the LC_5 and either AG_Treuth or AG_Puyau intensity derivations provide similar mean estimates of time in MVPA during-free living activity in 10-yr-old children.
机译:新型的加速度计Kenz Lifecorder EX(LC;日本名古屋Suzuken Co.Ltd),有望代替常用的Actigraph(AG:Actigraph LLC,佛罗里达州华尔顿堡滩),成为一种可行的监视器替代品。目的:本研究比较了自由活动条件下的LC和AG加速度计和Yamax SW-200计步器(DW)在儿童的步伐和光强度体力活动(PA)和中度至剧烈PA(MVPA)方面的时间。方法:参与者(N = 31,年龄= 10.2 +/- 0.4岁)从到达学校(上午7:45)直到上床,都穿着LC,AG和DW显示器。使用LC的两个单独的强度分类(LC_4和LC_5)和AG的四个分类(AG_Treuth,AG_Puyau,AG_Trost和AG_Freedson)来计算光照时间和MVPA强度。两种加速度计都将步长作为输出。 DW步骤是自记录的。重复测量方差分析用于评估重叠的监控器输出。结果:DW和LC步长之间没有差异(Delta = 200步长),但在DW和AG步长之间的成对比较中观察到无显着趋势(Delta = 1001步长,P = 0.058)。 AG检测到的步数明显大于LC(Δ= 801步,P = 0.001)。光强度活动分钟的估计范围从低点75.6 +/- 18.4分钟(LC_4)到高点309 +/- 69.2分钟(AG_Treuth)。 MVPA分钟的估计值范围从最低25.9 +/- 9.4分钟(LC_5)到最高112.2 +/- 34.5分钟(AG_Freedson)。 LC_5和AG_Treuth(增量= 4.9分钟)或AG_Puyau(增量= 1.7分钟)之间未发现MVPA的显着差异。结论:在儿童中,LC检测到的步数与DW相当,但步骤比AG少得多。当前结果表明,LC_5和AG_Treuth或AG_Puyau强度推导提供了类似的10岁儿童自由活动期间MVPA时间的平均估计值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号