首页> 外文期刊>Medical dosimetry: official journal of the American Association of Medical Dosimetrists >Is there a clinical benefit with a smooth compensator design compared with a plunged compensator design for passive scattered protons?
【24h】

Is there a clinical benefit with a smooth compensator design compared with a plunged compensator design for passive scattered protons?

机译:与用于无源散射质子的插入式补偿器设计相比,采用平滑的补偿器设计是否具有临床益处?

获取原文
获取原文并翻译 | 示例
           

摘要

In proton therapy, passive scattered proton plans use compensators to conform the dose to the distal surface of the planning volume. These devices are custom made from acrylic or wax for each treatment field using either a plunge-drilled or smooth-milled compensator design. The purpose of this study was to investigate if there is a clinical benefit of generating passive scattered proton radiation treatment plans with the smooth compensator design. We generated 4 plans with different techniques using the smooth compensators. We chose 5 sites and 5 patients for each site for the range of dosimetric effects to show adequate sample. The plans were compared and evaluated using multicriteria (MCA) plan quality metrics for plan assessment and comparison using the Quality Reports [EMR] technology by Canis Lupus LLC. The average absolute difference for dosimetric metrics from the plunged-depth plan ranged from -4.7 to +3.0 and the average absolute performance results ranged from -6.6% to +3%. The manually edited smooth compensator plan yielded the best dosimetric metric, +3.0, and performance, + 3.0% compared to the plunged-depth plan. It was also superior to the other smooth compensator plans. Our results indicate that there are multiple approaches to achieve plans with smooth compensators similar to the plunged-depth plans. The smooth compensators with manual compensator edits yielded equal or better target coverage and normal tissue (NT) doses compared with the other smooth compensator techniques. Further studies are under investigation to evaluate the robustness of the smooth compensator design. (C) 2015 American Association of Medical Dosimetrists.
机译:在质子治疗中,被动分散质子计划使用补偿器使剂量符合计划容积的远侧表面。这些设备使用切入式钻孔或平滑研磨的补偿器设计针对每个治疗领域由丙烯酸或蜡定制而成。这项研究的目的是调查使用平滑补偿器设计生成被动散射质子辐射治疗计划是否具有临床益处。我们使用平滑补偿器使用不同的技术生成了4个计划。我们选择了5个部位,每个部位选择5名患者进行剂量学测定,以显示足够的样本量。使用多准则(MCA)计划质量指标对计划进行比较和评估,以使用Canis Lupus LLC的质量报告[EMR]技术进行计划评估和比较。切入深度计划的剂量度量标准的平均绝对差在-4.7到+3.0之间,平均绝对性能结果在-6.6%到+ 3%之间。与深度计划相比,手动编辑的平滑补偿器计划产生了最佳的剂量度量+3.0和性能+ 3.0%。它也优于其他平滑补偿器计划。我们的结果表明,采用类似于平滑深度计划的平滑补偿器来实现计划的方法有多种。与其他平滑补偿器技术相比,具有手动补偿器编辑的平滑补偿器产生的目标覆盖范围和正常组织(NT)剂量相等或更好。正在研究进一步的研究,以评估平滑补偿器设计的耐用性。 (C)2015美国医学剂量学协会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号