首页> 外文期刊>Manual therapy. >A comparison of the reliability of the trochanteric prominence angle test and the alternative method in healthy subjects
【24h】

A comparison of the reliability of the trochanteric prominence angle test and the alternative method in healthy subjects

机译:股骨转子隆起角试验和替代方法在健康受试者中的可靠性比较

获取原文
获取原文并翻译 | 示例

摘要

A wide range of intra- and inter-rater reliabilities of the trochanteric prominence angle test (TPAT) has been reported. We introduced the transcondylar angle test (TCAT) as an alternative to the TPAT and using a smartphone as a reliable measurement tool for femoral neck anteversion (FNA) measurement. The reliabilities of the TPAT and the TCAT, the reliability of using a smartphone as a clinical measurement tool, and the correlation between the difference value of medial knee joint space (KJS) between rest and tested positions and the difference value between the TPAT and TCAT were assessed. Two physical therapists independently determined the reliabilities of the TPAT with a digital inclinometer, the TCAT with a digital inclinometer, and the TCAT with a smartphone in 19 hips of 10 healthy subjects (5 male and 5 female, 22.2±1.69 years). The medial KJS in rest and the tested position were assessed using a sonography. The intra-class correlation coefficients (ICC) for the intra-rater reliabilities of TPAT with a digital inclinometer (ICC=0.92), TCAT with a digital inclinometer (ICC=0.94) and a smartphone (ICC=0.95) in both testers were substantial. The inter-rater reliability of TPAT with a digital inclinometer was fair (ICC=0.48) while TCAT with a digital inclinometer (ICC=0.89) and a smartphone (ICC=0.85) were substantial. The correlation between the difference value of medial KJS between rest and tested positions and the difference value between TPAT and TCAT was low and statistically non-significant (r=0.114; p=0.325). The TCAT would be more reliable than the TPAT in inter-rater test. Using a smartphone is a clinically comparable measuring tool to adigital inclinometer.
机译:转子粗隆角测试(TPAT)的评估者内部和评估者之间的可靠性范围广泛。我们引入了con突角测试(TCAT)作为TPAT的替代产品,并使用智能手机作为用于股骨颈前倾(FNA)测量的可靠测量工具。 TPAT和TCAT的可靠性,使用智能手机作为临床测量工具的可靠性以及静止和测试位置之间的内侧膝关节间隙(KJS)的差值与TPAT和TCAT的差值之间的相关性被评估。两名物理治疗师分别用数字测斜仪,数字测斜仪TCAT和使用智能手机的TCAT在10名健康受试者的19髋(男性5例,女性5例,22.2±1.69岁)中确定了可靠性。使用超声检查评估静止的内侧KJS和测试位置。在两个测试仪中,使用数字测斜仪(ICC = 0.92),使用数字测斜仪(ICC = 0.94)和智能手机(ICC = 0.95)的TPAT的评定者内可靠性的类内相关系数(ICC)很大。 。使用数字测斜仪的TPAT在评估者之间的可靠性是中等的(ICC = 0.48),而使用数字测斜仪的TCAT(ICC = 0.89)和智能手机(ICC = 0.85)的可靠性很高。静止和测试位置之间的内侧KJS的差异值与TPAT和TCAT的差异值之间的相关性较低,且在统计学上无统计学意义(r = 0.114; p = 0.325)。在评估者间测试中,TCAT将比TPAT更可靠。使用智能手机是临床上可与数字测斜仪相媲美的测量工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号