摘要

The following inquiry has been taken from the Technical Questions and Answers e-mail archives. A member had a 4" jacketed reaction kettle repair question. A thru seal hose connection (h/c) had broken off. This break was close to the reactor body and was located 25 mm away from the large (4") ring seal. He was interested in feedback and comments as to the safest way to proceed with this project. Here are some of the solutions that were offered by other members.
机译:以下查询是从“技术问题和答案”电子邮件存档中获取的。一名成员有一个4英寸带夹套的反应釜维修问题。通封软管连接(h / c)断开了。此断裂靠近反应堆主体,距大(4英寸)密封圈25毫米。他对进行此项目的最安全方式的反馈和评论很感兴趣。以下是其他成员提供的一些解决方案。