首页> 外文期刊>Canadian Journal of Chemistry >Packed-column supercritical fluid chromatography with splitless flame ionization detection
【24h】

Packed-column supercritical fluid chromatography with splitless flame ionization detection

机译:填充柱超临界流体色谱,具有不分流火焰电离检测

获取原文
获取原文并翻译 | 示例
           

摘要

The design and characterization of a flame ionization detector(FID)that is compatible with the high flow rates of packed-column supercritical fluid chromatography (pSFC) is presented.The modified FID uses a large quartz burner(4.0 mm i.d.)in place of the conventional burner(0.4 mm i.d.)and operates a stable flame in the presence of gas flows tested up to nearly 3000 mL/min.This modification allows the full flow of effluent from a pSFC column(i.e.,splitless mode)to be directed into the FID.Results demonstrate that the modified FID yields response that is within a factor of 3 to that of a commercial FID.The attributes of the modified detector indicate that this approach could be a reliable and relatively simple means of achieving a splitless pSFC-FID system.
机译:提出了与填充柱超临界流体色谱(pSFC)的高流速兼容的火焰离子检测器(FID)的设计和特性。改进的FID使用大号石英燃烧器(内径4.0 mm)代替常规燃烧器(内径0.4 mm),在经过测试的气流高达3000 mL / min的情况下运行稳定的火焰。此修改允许将来自pSFC色谱柱的全部流出物(即,不分流模式)导入FID结果表明修改后的FID产生的响应是商用FID的三分之一。修改后的检测器的属性表明,此方法可能是实现不分流pSFC-FID系统的可靠且相对简单的方法。