首页> 外文期刊>Bulletin of the Korean Chemical Society >Simultaneous Fluorimetric Determination of On-line Preconcentrated HANs, DCAD and TCAD by Using RPLC with a Postcolumn Derivatization System
【24h】

Simultaneous Fluorimetric Determination of On-line Preconcentrated HANs, DCAD and TCAD by Using RPLC with a Postcolumn Derivatization System

机译:RPLC与柱后衍生系统同时荧光在线测定预富集的HANs,DCAD和TCAD

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

A simultaneous analytical method has been developed for the fluorimetric determination of haloacetonitriles (HANs) [dichloroacetonitrile (DCAN), trichloroacetonitrile (TCAN), dibromoacetonitrile (DBAN), halo-acetamides [dichloroacetamide (DCAD), and trichloroacetamde (TCAD)] in drinking water by using the combined on-line perconcentration/reversed phase liquid chromatography (RPLC)-postcolumn detection system. This on-line perconcentration system was achieved by employing a precolumn packed with a commercial solid phase extraction (SPE) sorbent for the enrichment and purification of the target analytes. The haloacetonitriles and haloacetamides were separated on CN analytical column in a 7.5% methanol-0.02 M phosphate buffered mobile phase at pH 3. The column effluents were reacted with postcolumn reagents of o-phthaldialdehyde (OPA) and sulfite ion at pH 11.5, to produce a highly fluorescent isoindole fluorophore, which were measured with a fluorescence detector. Under the optimized conditions for RPLC and the postcolumn derivatization system all of the coefficient of determination of the standard calibration curves for the target analytes were over 0.99 and had a linear range from 5 to 100 μg/L. The detection limits showed 1.6 μg/L for DCAD,0.1μg/L for TCAD,0.6 μg/L for DCAN-4.6μg/L for TCAN and 1 μg/L for DBAN/and the recoveries were ranged from 64 to 99% except for DCAD with precisions less than 4.9% in distilled water, and from 72(± 4%) to 116%(± 2%) in tap water.
机译:开发了一种同时分析方法,用于荧光测定饮用水中的卤代乙腈(HANs)[二氯乙腈(DCAN),三氯乙腈(TCAN),二溴乙腈(DBAN),卤代乙酰胺[二氯乙酰胺(DCAD)和三氯乙酰胺(TCAD)]通过使用组合的在线超浓缩/反相液相色谱(RPLC)-柱后检测系统。该在线浓缩系统是通过使用装有商业固相萃取(SPE)吸附剂的预柱来富集和纯化目标分析物而实现的。在pH为3的7.5%甲醇-0.02 M磷酸盐缓冲流动相中,在CN分析柱上分离卤代乙腈和卤代乙酰胺。使色谱柱流出物与邻苯二甲醛(OPA)和亚硫酸根离子的后柱试剂在pH 11.5下反应,生成用荧光检测器测量的高荧光异吲哚荧光团。在RPLC和柱后衍生系统的最佳条件下,目标分析物的标准校准曲线的所有测定系数均超过0.99,线性范围为5至100μg/ L。检出限为DCAD 1.6μg/ L,TCAD0.1μg/ L,DCAN0.6μg/ L,TCAN-4.6μg/ L和DBAN / 1μg/ L,回收率在64%至99%之间DCAD在蒸馏水中的精度低于4.9%,在自来水中的精度从72(±4%)降至116%(±2%)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号