首页> 外文期刊>Gastrointestinal Endoscopy >Image-guided biopsy in the esophagus through comprehensive optical frequency domain imaging and laser marking: a study in living swine.
【24h】

Image-guided biopsy in the esophagus through comprehensive optical frequency domain imaging and laser marking: a study in living swine.

机译:通过全面的光频域成像和激光标记在食道中进行影像引导活检:一项关于活猪的研究。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Random biopsy esophageal surveillance can be subject to sampling errors, resulting in diagnostic uncertainty. Optical frequency domain imaging (OFDI) is a high-speed, 3-dimensional endoscopic microscopy technique. When deployed through a balloon-centering catheter, OFDI can automatically image the entire distal esophagus (6.0 cm length) in approximately 2 minutes. OBJECTIVE: To test a new platform for guided biopsy that allows the operator to select target regions of interest on an OFDI dataset, and then use a laser to mark the esophagus at corresponding locations. The specific goals include determining the optimal laser parameters, testing the accuracy of the laser marking process, evaluating the endoscopic visibility of the laser marks, and assessing the amount of mucosal damage produced by the laser. DESIGN: Experimental study conducted in 5 swine in vivo. SETTING: Massachusetts General Hospital. MAIN OUTCOME MEASUREMENTS: Success rate, including endoscopic visibility of laser marks and accuracy of the laser marking process for selected target sites, and extent of the thermal damage caused by the laser marks. RESULTS: All of the laser-induced marks were visible by endoscopy. Target locations were correctly marked with a success rate of 97.07% (95% confidence interval, 89.8%-99.7%). Thermal damage was limited to the superficial layers of the mucosa and was observed to partially heal within 2 days. LIMITATIONS: An animal study with artificially placed targets to simulate pathology. CONCLUSIONS: The study demonstrates that laser marking of esophageal sites identified in comprehensive OFDI datasets is feasible and can be performed with sufficient accuracy, precision, and visibility to guide biopsy in vivo.
机译:背景:食管活检随机监测可能会出现抽样错误,导致诊断不确定性。光学频域成像(OFDI)是一种高速的3维内窥镜显微技术。通过气囊定心导管展开时,OFDI可以在大约2分钟内自动对整个远端食道(6.0厘米长)成像。目的:测试一种新的引导式活检平台,该平台允许操作员在OFDI数据集上选择感兴趣的目标区域,然后使用激光在相应位置标记食道。具体目标包括确定最佳激光参数,测试激光标记过程的准确性,评估激光标记的内窥镜可见性以及评估激光产生的粘膜损伤量。设计:在5只猪体内进行实验研究。地点:麻省总医院。主要观察指标:成功率,包括激光标记的内窥镜可见性和所选目标部位的激光标记过程的准确性,以及由激光标记引起的热损伤的程度。结果:所有激光诱导的标记都可以通过内窥镜观察到。正确标记目标位置的成功率为97.07%(95%置信区间,89.8%-99.7%)。热损伤仅限于粘膜表层,并在2天内观察到部分愈合。局限性:一项动物研究,其人工放置的靶标可以模拟病理。结论:该研究表明,在完整的OFDI数据集中识别出的食管部位进行激光标记是可行的,并且可以以足够的准确性,精确度和可见度进行,以指导体内活检。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号