首页> 外文期刊>European radiology >Breast dynamic contrast-enhanced examinations with fat suppression: Are contrast-agent uptake curves affected by magnetic field inhomogeneity?
【24h】

Breast dynamic contrast-enhanced examinations with fat suppression: Are contrast-agent uptake curves affected by magnetic field inhomogeneity?

机译:带有脂肪抑制的乳房动态对比增强检查:磁场不均匀性会影响对比剂摄取曲线吗?

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives: To investigate the effect of magnetic field heterogeneity in breast dynamic contrast-enhanced examinations with fat saturation (DCE-FS). Methods: The magnetic field was mapped over the breasts in ten patients. DCE-FS was undertaken at 1.5 T with fast spoiled gradient echoes and spectrally selective fat saturation. Signal intensity was calculated for T1 values 25-1,200 ms both on and off resonance, and results were verified with a test object. Clinical examinations were evaluated for the predicted effects of field heterogeneity. Results: Magnetic field was found to vary by 3.6 ± 1.2 ppm over the central transaxial slice and 5.1 ± 1.5 over the whole breast volume (mean ± standard deviation). Computer simulations predict a reduction in the dynamic range if field heterogeneity leads to unintended water suppression, and distortion to CA uptake curves due to fat suppression failure (for fat containing pixels). A compromise between dynamic range and fat saturation performance is required. Both water suppression and fat suppression failure are apparent in clinical examinations. Conclusion: Magnetic field heterogeneity is likely to reduce the sensitivity of DCE-FS by distorting the CA uptake curves because of fat suppression failure (for fat containing pixels) and by reducing the dynamic range because of unintended water suppression. Key Points: ? Magnetic field heterogeneity is significant in breast magnetic resonance. ? Contrast-agent uptake curves are distorted by a non-uniform magnetic field. ? Radiologist must be aware of possibility of distortion to interpret uptake curves correctly. ? Compromise between fat suppression and dynamic range is required.
机译:目的:研究磁场异质性在乳腺动态对比增强检查中对脂肪饱和度(DCE-FS)的影响。方法:将磁场映射到十名患者的乳房上。 DCE-FS是在1.5 T下进行的,梯度梯度回波快速变坏,并且光谱选择性脂肪饱和。计算开和关共振时T1值25-1,200 ms的信号强度,并用测试对象验证结果。对临床检查进行了场异质性预测效果的评估。结果:发现中央跨轴切片的磁场变化为3.6±1.2 ppm,整个乳房体积的磁场变化为5.1±1.5(均值±标准差)。如果场异质性导致意外的水抑制作用,并且由于脂肪抑制作用失败(对于含脂肪的像素),CA吸收曲​​线发生畸变,计算机模拟将预测动态范围的减小。在动态范围和脂肪饱和性能之间需要折衷。水分抑制和脂肪抑制失败在临床检查中均显而易见。结论:磁场异质性可能会由于脂肪抑制失败(对于含脂肪的像素)而扭曲CA吸收曲​​线,并由于意外的水抑制而降低动态范围,从而降低DCE-FS的灵敏度。关键点: ?磁场异质性在乳房磁共振中很重要。 ?造影剂吸收曲线会因不均匀的磁场而失真。 ?放射科医生必须意识到变形的可能性,以正确解释摄取曲线。 ?需要兼顾脂肪抑制和动态范围。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号